DOI: https://doi.org/10.21203/rs.2.24611/v2
Self-expandable metal stent placement is a well-accepted palliative therapy for the treatment of malignant obstructive jaundice (1, 2). Compared with external catheter drainage, stent placement not only improves patient quality of life but also avoids bile loss. However, stent placement for hilar biliary obstruction is more complicated than that for distal biliary obstruction, as bilateral stenting with two or more stents is often required. Side-by-side (SBS) and stent-in-stent (SIS) are the two most commonly used techniques for bilateral stent deployment (3, 4).
Comparisons of these two techniques are very limited in the literature and the results from previous studies are conflicting (5-8). There is no conclusive answer to the question of which technique is better. Moreover, all stent deployment procedures in the limited previous studies were performed endoscopically. Thus, it is worth further investigating these two techniques with the percutaneous approach.
The purpose of this study was to compare the clinical efficacy and safety of side-by-side and stent-in-stent deployment via bilateral percutaneous routes for malignant hilar biliary obstruction.
Patient Selection and Stents
The study was approved by our institutional review board. We retrospectively reviewed the medical records and images of 69 patients who underwent bilateral metallic stent placement using SBS or SIS techniques for the treatment of unresectable malignant hilar biliary obstructions between July 2012 and April 2019 in our department. Inclusion criteria of this study were: 1. diagnosis of malignant unresectable biliary hilar obstruction based on laboratory and imaging or pathological findings; 2. without any previous biliary drainage prior to the admission; 3. with a regular follow up. Four patients were excluded, three of them were lost to follow up and the other one received external drainage in other hospital. In the remaining 65 patients who met inclusion criteria, 38 patients underwent stent placement using the SBS technique (SBS group) and the other 27 patients received implantation of stents with the SIS technique (SIS group).
Two types of uncovered self-expandable metallic stents (E-Luminexx (Bard Peripheral Vascular, Tempe, AZ), Microtech (Microtech, Nanjing, China)) with a diameter of 8 mm and lengths of 60 mm-100 mm were used in this study.
Procedure
Prior to the procedure, the biliary hilar strictures were assessed on contrasted enhanced computed tomography (CT) and/or magnetic resonance cholangiopancreatography (MRCP). To relieve the pain during the procedure, intravenous sedation with oxycodone was applied.
SBS group
The procedures were carried out under fluoroscopic with/without ultrasonic guidance. After successful puncturing of the right intra-hepatic bile duct with a 22G Chiba needle (Cook, Bloomington, IN), a NEFF set was inserted into the bile duct. The outer cannula of the NEFF set was kept for cholangiography to evaluate the stricture site. Then, a 0.035-inch guidewire was advanced and the outer cannula of the NEFF set was exchanged with a 5F Headhunter or Cobra catheter (Cook, Bloomington, IN) to navigate through the obstruction. After passing through the stricture and subsequently measuring its length, a 6F or 8F sheath (Terumo, Tokyo, Japan) was inserted and the guidewire was kept inside with its tip in the distal duodenum. Then, the left bile duct was punctured and the following steps were the same as the right side. Two bare SEMSs were advanced over the two guidewires in each side and deployed on the centers of the bilateral strictures. Each end of the stent should be 1.5- to 2-cm longer than the biliary stricture. After stenting, repeat cholangiography was performed to verify the stent patency and the two puncture approaches were occluded through the sheaths using gelfoam pledgets (Fig. 1).
SIS group
The puncture technique was the same as mentioned above. After successful stenting in one side, a 0.035-inch guidewire and a 5F Headhunter or Cobra catheter (Cook, Bloomington, IN) in the other side was inserted into the duodenum through the mesh of the contralateral stent at the biliary hilum. A 6F or 8F long sheath was inserted over the guidewire to dilate the mesh. Then, an uncovered SEMS was advanced and deployed across the stricture. Cholangiography was repeated to evaluate the bilateral stent patency and the two puncture approaches were occluded with gelfoam pledgets (Fig. 2).
Follow Up
After procedures, the patients were regularly followed up to June 2019 or until the death of the patients. The follow-up visits consisted of outpatient and telephone interviews. Outpatient interviews were performed one month later after stent placement. Telephone consultations were performed at two weeks and then every three months after stenting. If obstructive jaundice recurred which was confirmed by elevation of bilirubin level and dilatation of bile ducts on CT, the patient was encouraged to receive stent revision or external drainage.
Technical and Clinical Assessment
Technical success was defined as successful deployment of the bilateral stents in the appropriate positions and good contrast flow through the stents into the duodenum.
Clinical outcome was evaluated on the following aspects, including the improvement of jaundice at 1 week and 1 month after the procedure, complications, stent patency period, and overall survival. The significant improvement of jaundice was defined by a decrease in serum bilirubin level of more than 20% at 1 week and more than 75% at 1 month after stent placement compared with the preoperative baseline (9, 10). The complications were divided into major and minor complications according to the reporting standards of the Society of Interventional Radiology (11). Major complications were defined as those requiring major therapy, an unplanned increase in level of care or prolonged hospitalization (> 48 h), or causing permanent adverse sequelae or death. Other complications were regarded as minor. Stent patency period was defined as the time interval between the initial stent placement and recurrence of jaundice or the last follow-up or death of the patients without evidence of jaundice. If a patient ceased without recurrent jaundice, the stent patency period was considered to be the same as the duration of the survival. Survival was calculated from the time of the initial stent placement to death from any cause or the last follow-up visit. Data of stent patency and survival were censored for patients who remained alive at the time of this writing.
Statistics
The independent t-test was used for the comparison of continuous variables. The chi-squared test or Fisher’s exact test was used for comparing categorical variables, depending on the scale level. Survival curves were calculated by Kaplan–Meier method and compared by log-rank test. A two-tailed P-value lower than 0.05 was considered as statistically significant. All analyses were carried out using the SPSS version 15.0 software (SPSS, Chicago, Illinois, USA).
Of the 65 patients included in this study, 37 were male and the other 28 were female, with a mean age of 64.1 years (range: 24-92). The primary causes of biliary obstruction were cholangiocarcinoma in 27 patients, gallbladder cancer in 17 patients, hepatocellular carcinoma in 11 patients, and metastatic nodes in 10 patients. According to the Bismuth classification of perihilar cholangiocarcinoma, 17 patients belonged to type II, 38 patients to type III, and 10 patients to type IV. The baseline characteristics of the patients in the two groups are listed in Table 1, and no significant differences were found between the two groups (P>0.05).
Technical success was achieved in all patients. The most commonly used stents had sizes of 8*80 mm and 8*60 mm. One week after the procedures, a 20% reduction in serum bilirubin level was achieved in 89% (34/38) of the patients in the SBS group, and only in 67% (18/27) of the patients in the SIS group (P=0.03). One month after stenting, however, there was no significant difference in the proportion of patients with a 75% reduction in serum bilirubin level between the two groups (SBS vs. SIS, 92% vs. 89%, P>0.05).
Major complications only occurred in one patient in the SBS group. The patient was 79 years old and developed acute pancreatitis after the procedure. Antibiotics and protein degeneration enzyme inhibitors were given. However, the patient’s condition did not improve, and he died of renal failure eight days after the procedure. Minor complications, including cholangitis, cholecystitis, pancreatitis, and peritonitis, occurred in 18% (7/38) of the patients in the SBS group and 33% (9/27) of the patients in the SIS group (P>0.05). Cholangitis was found to be more frequent among the patients in the SIS group than among those in the SBS group (30% vs. 8%, P=0.04).
The median follow-up time was 6 months (range, 2-12 months) in the SBS group and 5 (range, 2-14 months) months in the SIS group. The median stent patency duration was significantly longer in the SBS group (149 days) than in the SIS group (75 days; P = 0.02). (Fig. 3). During the follow-up period, stent occlusion occurred in seven patients in the SBS group (stent duration: 55-250 days) and ten patients in the SIS group (stent duration: 20-160 days) (P>0.05). Among these patients, nine patients underwent external drainage, seven patients underwent stent revision using new stents, and one patient only received conservative therapies due to poor general conditions. The median overall survival in the SBS group was 155 days, which did not differ significantly from the 143 days in the SIS group (P>0.05) (Fig. 4). The main results of the two groups are listed in Table 2.
In patients with malignant hilar biliary strictures, drainage of more than 50% of the liver volume usually requires bilateral stent implantation unless there is a definite hypertrophic lobe (12). Several retrospective studies have shown that bilateral metal stent insertion leads to longer stent patency and patient survival than unilateral metal or plastic stent insertion (13-15). Bilateral stent placement can be performed endoscopically or percutaneously (16, 17). The decision to use either an endoscopic or percutaneous approach mainly depends on local expertise (18)..
Currently, two methods of stent placement are most commonly used for hilar strictures: SBS and SIS. Previously, there were only a few studies that compared these two different techniques. In 2012, Naitoh et al. (5) initially evaluated these two techniques and found that the SBS technique tended to lead to a longer stent patency than the SIS technique, although the SBS technique had more complications. However, later studies did not find any significant differences in technical success, complications, or stent occlusion (6-8). Thus, it is still contrroversial which technique is better. Additionally, all the stents in these studies were placed under endoscopy, and therehas been no comparison of these two techniques performed via the percutaneous transhepatic approach.
In this study, the stents were all placed percutaneously using these two techniques. The technical success rate was 100% in both groups. However, in the SIS group, the mesh of the first stent must be passed through before deploying the second stent, usually requiring a long sheath or a balloon catheter to dilate the mesh. Thus, the SIS approach is more time consuming and technically demanding. In addition, we found that the bilirubin level after the procedures was reduced more quickly in the SBS group than in the SIS group. This may be due to the different stent configurations in the two groups. The two parallel stents in the SBS group offer a larger flow area in the common hepatic duct than the two stents with an SIS configuration, which may allow the bile to be drained more effectively.
In addition, the obstructive jaundice improved quicker in the SBS group, and the duration of stent patency was also longer in the SBS group than that in the SIS group. Theoretically, the SBS configuration provides a larger flow area than the SIS configuration, which may delay the event of a stent obstruction in the common bile duct caused by tumor ingrowth.
In this study, the procedure-related complication rates were 18.4% in the SBS group and 33.3% in the SIS group, which were similar to the rates in the papers that performed the procedures endoscopically (5, 6). Noticeably, cholangitis was less frequently observed in the SBS group than in the SIS group. The placement of two stents may result in incomplete biliary drainage in Bismuth III and IV strictures, which could cause subsequent cholangitis due to undrained ducts. However, the composition of the two groups were similar, which could offset this impact. Thus, the bile may be drained more effectively in the SBS group owing to the large flow area of the common hepatic duct, which could decrease the rate of bile infection. This result is different from a previous study (5). It has been reported that excessive expansion of the two SBS stents might cause portal vein occlusion and increase the rate of cholangitis (5).
This study has several limitations. First, this was a retrospective study with a small number of patients. Second, the selection of stent type and the technique of stent deployment mainly relied on the operators’ preferences in this study, which may introduce bias and influence the outcome. Therefore, a prospective, randomized controlled trial with the same type of stent is warranted to further clarify the differences between the SBS and SIS techniques performed through the percutaneous approach.
In conclusion, percutaneous transhepatic bilateral stenting using either the SBS or SIS techniques is safe and effective for the treatment of malignant hilar biliary obstruction. Compared with SIS, SBS offers quicker improvement of jaundice, a lower incidence of cholangitis after the procedure, and a longer stent patency period.
side-by-side (SBS)
stent-in-stent (SIS)
Eastern Cooperative Oncology Group (ECOG)
Hepatocellular Carcinoma (HCC)
Ethics approval and consent to participate
All procedures performed in this study were in accordance with the ethical standards of ethical committee of the First Affiliated Hospital of Nanjing Medical University and with the 1964 Helsinki declaration and its later amendments. Written informed consent was obtained from individual or guardian participants included in the study.
Consent for publication
The patients gave written consent for their personal or clinical details along with any identifying images to be published in this study.
Availability of data and materials
The datasets used and analysed during the current study are available from the corresponding author on reasonable request.
Competing interests
The authors declare that they have no competing interests.
Funding
This study was not supported by any funding.
Authors’ contributions
WZ. Z and HB. S conceived of and designed the study; WZ. Z, S. L, and ZQ. Y acquired and analyzed data. WZ. Z and S. L wrote the first draft. S. L, YT. X, JZ. W,and HD. X revised the manuscript for important intellectual content critically. All authors made substantial contributions towards drafting the manuscript, reviewing the final manuscript for intellectual content. All of the authors read and approved the final manuscript.
Acknowledgements:
Not applicable.
Characteristics
|
SBS group
|
SIS group
|
p value
|
---|---|---|---|
Pt. No.
|
38
|
27
|
|
Gender
|
0.30
|
||
Male
|
19 (50.0)
|
10 (37.0)
|
|
Female
|
19 (50.0)
|
17 (63.0)
|
|
Age (y)
|
63.0 ± 12.4
|
65.3 ± 13.5
|
0.48
|
ECOG
|
0.48
|
||
0
|
3 (7.7)
|
2 (6.2)
|
|
1
|
23 (61.5)
|
20 (75)
|
|
2
|
12 (30.8)
|
5 (18.8)
|
|
Obstruction causes
|
0.72
|
||
Cholangiocarcinoma
|
18 (47.3)
|
9 (33.4)
|
|
Gallbladder cancer
|
9 (23.7)
|
8 (29.6)
|
|
HCC
|
6 (15.8)
|
5 (18.5)
|
|
Others
|
5 (13.2)
|
5 (18.5)
|
|
Bismuth classification
|
0.68
|
||
Type II
|
9 (23.7)
|
8 (29.6)
|
|
Type III
|
22 (57.9)
|
16 (59.3)
|
|
Type IV
|
7 (18.4)
|
3 (11.1)
|
|
Further chemotherapy
|
6 (15.8)
|
4 (14.8)
|
0.91
|
Note-Values presented as mean ± standard deviation where applicable. Values in parentheses are percentages.
ECOG = Eastern Cooperative Oncology Group; HCC = Hepatocellular Carcinoma
|
Outcomes
|
SBS group (n = 38)
|
SIS group (n = 27)
|
p value
|
---|---|---|---|
Technical success
|
38 (100)
|
27 (100)
|
1
|
Reduction of bilirubin level
|
|||
By 20% at 1 week
|
34 (89.5)
|
18 (66.7)
|
0.03
|
By 75% at 1 month
|
35 (92.1)
|
24 (88.9)
|
0.69
|
Complications
|
|||
Major complication
|
1
|
||
Acute renal failure
|
1 (2.6)
|
0
|
|
Minor complications
|
7 (18.4)
|
9 (33.3)
|
0.24
|
Cholangitis
|
3 (7.9)
|
8 (29.6)
|
0.04
|
Cholecystitis
|
1 (2.6)
|
0
|
1
|
Pancreatitis
|
2 (5.3)
|
1(3.7)
|
1
|
Peritonitis
|
1 (2.6)
|
0
|
1
|
Stent occlusion
|
7 (18.4)
|
10 (37)
|
0.09
|
Note-Values in parentheses are percentages.
|