The precise input of flocculant (PAC) and coagulant aid (PAM) into phosphate wastewater is a key problem to degrade the phosphate content in sewage water and make the total phosphate (TP) and suspended pollutants (SS) in sewage water reach the discharged standard. In this paper, a new method combining fuzzy control technology with wastewater treatment control system is proposed to establish an automatic control system suitable for phosphates removal treatment. Based on experiment data and current experience, the membership function and fuzzy rules are set, and the fuzzy control technology is obtained with simulation analysis, and the efficient treatment of sewage water was realized. It can be seen from the results that the fuzzy control technology could be applied to the phosphate removal control system for treating sewage water, and the standard of stable, accurate and efficient sewage treatment has been realized.

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

Figure 7

Figure 8

Figure 9

Figure 10

Figure 11
The full text of this article is available to read as a PDF.
No competing interests reported.
Loading...
Posted 29 Jan, 2021
On 07 Feb, 2021
Received 04 Feb, 2021
On 02 Feb, 2021
On 30 Jan, 2021
Invitations sent on 28 Jan, 2021
On 28 Jan, 2021
On 26 Jan, 2021
On 26 Jan, 2021
On 25 Jan, 2021
Posted 29 Jan, 2021
On 07 Feb, 2021
Received 04 Feb, 2021
On 02 Feb, 2021
On 30 Jan, 2021
Invitations sent on 28 Jan, 2021
On 28 Jan, 2021
On 26 Jan, 2021
On 26 Jan, 2021
On 25 Jan, 2021
The precise input of flocculant (PAC) and coagulant aid (PAM) into phosphate wastewater is a key problem to degrade the phosphate content in sewage water and make the total phosphate (TP) and suspended pollutants (SS) in sewage water reach the discharged standard. In this paper, a new method combining fuzzy control technology with wastewater treatment control system is proposed to establish an automatic control system suitable for phosphates removal treatment. Based on experiment data and current experience, the membership function and fuzzy rules are set, and the fuzzy control technology is obtained with simulation analysis, and the efficient treatment of sewage water was realized. It can be seen from the results that the fuzzy control technology could be applied to the phosphate removal control system for treating sewage water, and the standard of stable, accurate and efficient sewage treatment has been realized.

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

Figure 7

Figure 8

Figure 9

Figure 10

Figure 11
The full text of this article is available to read as a PDF.
No competing interests reported.
Loading...