2.1 Ethical statement
This study was approved by the Medical Ethics Review Committee at Kyoto Prefectural University of Medicine approved. It was registered at the University hospital Medical Information Network (UMIN 000027940). After establishing the clinical trials act in Japan, the study was re-approved by the Clinical Research Review Board at Kyoto Prefectural University of Medicine in March 2019, and was registered in Japan Registry of Clinical Trials (JRCT s052180172). Subjects and their parents/guardians will receive detailed explanation about the study and informed consent will be obtained prior to the study. The study sponsor is SEED Co. Ltd. Seed was not involved in any or all of the study design, data collection, management, analysis, and interpretation, the subsequent preparation of the study report, or the decision to submit the final report for publication.
2.2 Study design
This is a prospective therapeutic intervention, multicenter, randomized, double masked, parallel group comparison study, which will be conducted at Department of Ophthalmology, Kyoto Prefectural University of Medicine and Department of Ophthalmology, University of Tsukuba. The subjects will be independently recruited to compare standard and multifocal SCL (specially controlled medical devices).
2.3 Subjects
The subjects of this study will be elementary school children with highly progressive mild to moderate myopia. Children, who have binocular vision disorder, amblyopia or manifest strabismus, and eye related diseases other than myopia, are excluded because they might affect the evaluation of outcomes. Children with any eye disorders in which contact lenses are contraindicated will also be excluded from the study.
(1) Inclusion criteria
1) First to sixth grade male and female elementary school students.
2) Children with worsened visual acuity based on the school examination within the previous year compared to that from the previous examinations.
3) Children who can be examined using cycloplegics.
4) Cycloplegic refraction criteria:
- Spherical equivalent power within the range of -1.00 D to -6.00 D in both eyes.
- Difference in the spherical equivalent power between eyes less than 1.50 D.
- Astigmatic power within ±1.50 D.
- Corrected distance visual acuity with glasses 1.0 or higher.
- Intraocular pressure within the normal range.
5) Children who can visit the study site and receive examinations on the scheduled days.
6) Children and their parents/guardians who provide signed informed consent to participate in the study.
(2) Exclusion criteria
Children with any of the following are excluded.
- Binocular vision disorder
- Amblyopia or manifest strabismus
- The difference in the spherical equivalent power with and without cycloplegic 1.50 D or higher in both eyes.
- Eye-related diseases other than myopia
- Systemic diseases that affect vision or refractive error
- Past myopia control therapy, such as bifocal glasses, progressive multifocal lenses, orthokeratology lenses, and drug treatment.
- Children who are determined by investigators to be inappropriate to participate in the study.
2.4 Sample size and randomization
The planned sample size is 50 subjects each at both Kyoto Prefectural University of Medicine and University of Tsukuba, a total of 100 subjects. The sample size is based on previous published data. Progression of myopia with multifocal SCL and that with standard therapy such as glasses were assumed to be -0.54 D/year and -0.84 D/year, respectively, based on a previous study conducted in US11, and standard deviation (SD) was assumed to be 0.66 D based on our previous study12. Considering that approximately 20% of the subjects would be unevaluable due to study withdrawal, etc., 50 subjects in each group and a total of 100 subjects were determined to be included in this study to detect a between-group significance (alpha=0.05, two sided and power=90%). Adaptive randomization will be performed to avoid any accidental bias between the two groups. Adaptive stratified sampling will be carried out using the minimization method with genders, grades, and study sites as allocation factors. Once consent is obtained, a fax of the case entry is sent and the allocation of the case is sent back.
2.5 Study therapy
Eligible subjects will be randomly assigned to wear standard SCL SEED 1dayPure UP or SEED 1dayPure UP Flex with +0.50 D add power in the peripheral areas (SEED Co. Ltd., Tokyo, Japan, Figure1). Contact lens power correction will be determined based on the results of the cycloplegic refraction. Slit-lamp microscopy examination of anterior ocular segment and interviews will be performed 2 weeks and 1, 3, 6, 9, 12, 15, 18, 21 and 24 months after the allocation of the subjects. Cycloplegic refraction, axial length, and aberrations (Wavefront sensor, Topcon Corporation, Tokyo, Japan) will be measured 2 weeks and 0.5, 1, 1.5 and 2 years after the allocation. If myopia progresses and the decimal visual acuity with SCL becomes less than 1.0, the contact lenses will be replaced. A study flow chart is shown in Figure 2.
2.6 Outcome measurements
Axial length was measured using noncontact partial coherence interferometry. The cycloplegic refraction, objective spherical power, astigmatic power and axis, the objective spherical equivalent power, and the mean corneal refractive power will be measured using an auto-refractometer under cyplegin 1% eye drops. Decimal visual acuity will be examined by orthoptists using the Landolt-C chart. Total higher order, coma-like, spherical-like and spherical aberrations, as well as pupil diameters for cornea/ ocular were measured with or without cycloplegic agents by using the Wavefront sensor KR-1W®. The difference of each measurement points from the baseline is evaluated. The meaning of "double-masked" is that the subjects and examiners do not know who is in the target group and who is in the control group. An external data center knows whether each case is a subject or a control. The analysis is done in the data center, but in a different department than the allocation.
Wearing conditions of SCL and cornea/ conjunctiva will be examined by the slip-lamp microscopy at each visit. Subjects’ backgroud characteristics will be obtained during the interview at the first visit of the study site. If a serious adverse event occurs, it should be reported to the President in accordance with the procedures. Serious adverse events should be listed in the paper. Medical interviews and Slit lamp microscopy will be conducted at each hospital visit to identify adverse events. Clinically important adverse events will be described in the paper. If any health damage occurs in relation to this clinical research, it will be compensated by the clinical research insurance purchased for this clinical research.
We planned to give the patients only a three-month supply of contact lenses and require them to visit the clinic every three months. Due to the prevalence of coronavirus, even if hospital visits do not occur as per protocol, contact lenses are being sent to minimize dropouts.
We plan to publish our results in a paper and then report them at a conference, as well as introduce them at local lectures. There are no plans for interim and secondary analysis. There are no plans for sharing of the data.
2. 7 Statistical analyses
All data will be analyzed based on the 'intention-to-treat' analysis. The primary analysis will be performed in the full analysis set (FAS), and robustness of the results will be explored through sensitivity analysis in the per-protocol set (PPS). The full analysis set (FAS) refers to all subjects who consented to start wearing contacts, and the PPS refers to subjects who were able to wear contacts on schedule for two years. No interim analysis is planned.
Data management
INCREASE Co. Ltd., Tokyo, Japan will act as a data center, and manage and handle study data that include data cleaning.
Data analyses
Summary statistics will be calculated for test values and change values at the end of the observation period (24 months) from the baseline (2 weeks). Between-group comparisons will be performed using the mixed effects model for repeated measures in both eyes, and individuals as random effects. The significance level is set at 5% (two-sided). All statistical analyses were performed using SAS version 9.4 (SAS Institute Inc., Cary, NC, USA) software.
2. 8 Data monitoring and audits
Contracted monitoring organization is INCREASE Co. Ltd. The data center will perform the central data monitoring using the electronic data of the case report forms. Central monitoring will identify missing values and ask each facility to make up for them. If it is truly deficient, it was noted. Data monitoring at study sites will also be performed by using sampled subjects. Results will be reported after monitoring.
Contracted auditing organization is INCREASE Co. Ltd. Results will be reported after audit.