Examination of Endobronchial Ultrasound-guided Transbronchial Needle Aspiration Using a Puncture Needle With a Side Trap

DOI: https://doi.org/10.21203/rs.3.rs-244743/v1

Abstract

Background:

Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is useful for diagnosing hilar and mediastinal lymph node enlargement; however, specimens obtained are often small and inadequate for pathologic diagnosis. In June 2017, EchoTip ProCore®, a puncture needle with a side trap, was launched in Japan.

Methods:

In this single-center prospective interventional study, 57 patients with lymph node or tracheal tumors were diagnosed using EBUS-TBNA with EchoTip ProCore® between June 2017 and February 2020.

Results:

EBUS-TBNA was performed for 57 patients, 1 had a cyst, 1 had necrotic tissue, and 2 had inadequate specimens; however, the remaining 53 patients had sufficient specimen for histologic diagnosis. The following pathologic subtypes were diagnosed: non-small cell lung cancer, 22; small cell lung cancer, 8; cancer of unknown primary, 2; neuroendocrine tumor (G2) recurrence, 1; lymphoma, 2; metastatic renal cell carcinoma, 3; thymoma recurrence, 1; sarcoidosis, 4; tuberculosis, 1; and non-malignancy, 9. None of the patients had complications. Among 13 patients with inadequate specimens or without malignancy, only one patient was subsequently diagnosed with malignancy, and the median follow-up period was 300 days.

Conclusion:

EBUS-TBNA using EchoTip ProCore® can obtain a sufficient specimen size for pathologic diagnosis.

Introduction

Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a useful diagnostic modality for thoracic lymphadenopathy, including primary lung cancer, malignant lymphoma, tuberculosis, and sarcoidosis 1-3. Tissue and cytological specimens can be obtained using EBUS-TBNA. Notably, tissue samples obtained using this technique can undergo tests for epidermal growth factor receptor (EGFR) mutations and immunohistochemical screening for anaplastic lymphoma kinase (ALK) rearrangement in patients with non-small cell lung cancer (NSCLC). However, the specimens obtained are often small and inadequate for pathologic diagnosis. Specifically, only 66% (19/29) of specimens obtained using EBUS-TBNA at our hospital between 2015 and 2016 were adequate for histological diagnosis.

In June 2017, EchoTip ProCore®, a puncture needle with a side trap that had been previously released for gastrointestinal endoscopes, was launched in Japan. EchoTip ProCore® needles are available in different sizes, including 22- and 25-gauge needles. They are designed with a core trap proximal to the needle tip that receives the sample during fine-needle aspiration (FNA) through the needle tip (Figure 1). Therefore, EchoTip ProCore® is considered to obtain core biopsy for histologic evaluation rather than only cytological material, as in other needles 4. This study aimed to investigate the diagnostic utility of EBUS-TBNA with EchoTip ProCore® for mediastinal lymphadenopathy.

Materials And Methods

Patients selection

This single-center prospective interventional study was conducted at the Department of Respiratory Medicine, Yokohama Municipal Citizen’s Hospital (Kanagawa, Japan). We included patients with radiological features of mediastinal or hilar lymphadenopathy who underwent EBUS-TBNA between June 2017 and February 2020. Chest computed tomography (CT) was performed before EBUS-TBNA, which revealed at least one enlarged mediastinal or hilar lymphadenopathy of >10 mm in all patients except for two patients with a tumor around the trachea. Finally, we included 57 patients in this study.

EBUS-TBNA

All enrolled patients underwent EBUS-TBNA using a convex endobronchial ultrasound bronchoscope probe (BF-UC260FW; Olympus, Tokyo, Japan) under fentanyl-induced sedation (0.025-0.05 mg/body) and midazolam (1-3 mg/body). A 22- and 25-gauge EchoTip ProCore® Endobronchial HD Ultrasound Needle (Cook Japan Inc., Tokyo, Japan) was used. The 25-gauge needle was employed if contrast-enhanced CT revealed blood vessel enrichment in a lymph node or if there was a high suspicion of hypervascular tumor metastasis, including renal cell carcinoma. We performed 2-4 punctures using the traditional vacuum syringe method and slow-pull technique.

Slow-pull technique

Originally, the slow-pull technique involved slow stylet retraction with needle fanning in the mass. Ten to twenty to-and-fro movements were made with minimal negative pressure provided by slow pulling of the stylet. The stylet retraction length and duration was approximately 1 m and 40-60 s, respectively 5-7. However, to obtain larger specimens, we used a modified version of the slow-pull technique, where the stylet retraction length was 5-10 cm and there were 10-30 to-and-fro movements. Subsequently, the procedure was repeated several times.

IRB approval

The study protocol was approved by the independent ethics committee of the institutional review board of Yokohama Municipal Citizen’s Hospital (No. 20-11-11). Informed consent was obtained in the form of opt-out on the web-site. Those who rejected were excluded. Topical subheadings are allowed. Authors must ensure that their Methods section includes adequate experimental and

characterization data necessary for others in the field to reproduce their work.

Statement of human rights

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

Results

Patients characteristics

Table 1 presents the baseline characteristics. This study enrolled 57 patients who underwent EBUS-TBNA using EchoTip ProCore® between June 2017 and February 2020. We used 22- and 25-gauge EchoTip ProCore® for 51 and 6 patients, respectively. The median age was 71 (range: 18-89) years, and 44 (77%) patients were male. The stations of the punctured lymph nodes were as follows: 1 for #2R; 20 for #4R; 3 for #4L; 26 for #7; 4 for #11s; 2 for #11i; and 2 for #11L. In all patients, the lymph nodes were in contact with the trachea or bronchial wall. Additionally, a right upper lobe tumor and pleural mass were punctured in two separate patients (Table 2). Among 57 patients, 60 lymph nodes were punctured, with two lymph nodes being punctured in three patients. The median maximum diameter of the target lesion was 27 (range: 14-70) mm.

EBUS-TBNA

Figure 1 illustrates the slow-pull technique using EchoTip ProCore®. As shown in Figure 1(A), the puncture is repeated with gradual pulling out of the stylet. Figure 1(B) presents an ultrasound image of EchoTip ProCore®. There is a side trap on the central tip side that shaves off the tissue. Figure 2 shows the tissue samples obtained using EchoTip ProCore®. Figure 2(A) presents a tissue sample obtained using a 22-gauge EchoTip ProCore® where the #11i lymph node was punctured. Hematoxylin-eosin staining showing large, strongly atypical cells, as well as positive TTF-1 staining, led to a histological diagnosis of metastatic lung adenocarcinoma. Subsequently, PD-L1 immunohistochemistry (IHC) revealed that 95% of the cells were positive; however, the cell number had been reduced by re-thinning (Figure 3). Figure 2(B) presents details of the other patients. There was lymph node enlargement of the right supraclavicular fossa and mediastinum; subsequently, EBUS-TNBA with EchoTip ProCore® was performed to differentiate among lymphoma, lymphoproliferative disease, and mediastinal lung cancer. A 22-gauge EchoTip ProCore® was used for #4R lymph node puncture. The lymph node was soft, and the tissue was obtained using the slow-pull technique, which yielded a large tissue with a size >10 cm, as shown in Figure 2(B). Pathological examination revealed an epithelioid granuloma; moreover, the interferon-gamma release assay for tuberculosis was positive; thus, the patient was diagnosed as having active tuberculosis. Only one case of suspected sarcoidosis with bronchoalveolar lavage (BAL) developed pneumonia after bronchoscopy, probably owing to BAL, which was positive for the pneumococcal urinary antigen and was relieved by oral levofloxacin treatment. None of the patients had massive bleeding, mediastinitis, or pneumothorax.

Pathological diagnosis

Among 57 patients, one had a cyst, one had necrotic tissue, and two had inadequate specimens; however, the remaining 53 (93%) patients had sufficient specimen for histologic diagnosis using EBUS-TBNA (Figure 3). The following pathologic subtypes were diagnosed: NSCLC, 22; small cell lung cancer (SCLC), 8; cancer of unknown primary (squamous cell carcinoma), 2; neuroendocrine tumor (G2) with thymus origin recurrence, 1; lymphoma, 2; metastatic renal cell carcinoma, 3; thymoma recurrence, 1; sarcoidosis, 4; tuberculosis, 1; and non-malignancy, 9. Moreover, cytology revealed that 68% (39/57) of patients were class III or higher. A patient with necrosis on histological examination was diagnosed as having SCLC based on cytological examination. Two patients lacked a definitive diagnosis based on histological examination; however, cytological examination was indicative of class III, and a lymphoma was detected on surgical lymph node biopsy. One of the 10 patients with class II according to cytological examination was diagnosed as Hodgkin's lymphoma based on surgical lymph node biopsy. Among the remaining patients, 8 were followed up, with 1 being excluded after being requested to be examined in another hospital. The median observation period for the 8 patients was 300 (range 223-665) days. However, for one patient who underwent lung cancer surgery, CT and positron emission tomography did not reveal changes in the punctured lymph nodes; however, brain recurrence occurred.

Histological diagnosis revealed lung cancer in 97% (30/31) of patients, and EBUS-TBNA with EchoTip ProCore® was used for diagnosis in all patients, including cytological diagnosis.

PD-L1 immunohistochemistry

The PD-L1 status was measured based on IHC using the PD-L1 IHC 22C3 PharmDx “dako” (Agilent Technologies Japan, Ltd.). Among 22 NSCLC patients, IHC of PD-L1 using the 22C3 antibody was possible in 19 patients except for 1 patient each where EBUS-TBNA was performed to differentiate between lung and breast cancer recurrence for staging purposes and to search for T790M mutation in EGFR-positive NSCLC, respectively. The PD-L1 tumor protein scores (TPSs) were ≥50%, 1%-49%, and <1% in 8 (42%), 5 (26%), and 6 (32%) patients, respectively (Table 3).

Discussion

Endoscopic ultrasound-FNA using EchoTip ProCore® was primarily employed in gastroenterology (especially in pancreatic cancer) and rarely in the respiratory field 8, 9. To our knowledge, this is the first report regarding the large-scale utility of EBUS-TBNA with EchoTip ProCore®. Bronchoscopic examination is widely used for initial diagnosis. Specifically, EBUS-TBNA is considered the first choice for mediastinal lymphadenopathy given that it has an almost similar diagnosis rate as mediastinoscopy and is minimally invasive 10.

Treatment of advanced lung cancer has dramatically changed since the discovery of the EGFR gene mutation in the 2000s and various driver gene mutations, including ALK rearrangement 11-13. Furthermore, nivolumab, which is a programmed death-1 antibody, was approved in December 2015 in Japan; subsequently, multiple immune checkpoint inhibitors have been approved 14-17. The PD-L1 expression rate in tissues is an important predictor of the effect of immune checkpoint inhibitors 14, 15. Therefore, EBUS-TBNA with mediastinal lymphadenopathy has been a useful procedure for lung cancer. There was an increasing need for a reliable method to obtain tissue samples. From 2015 to 2016, EBUS-TBNA was performed in 29 cases at our hospital; however, tissue diagnosis was possible in 19 cases (66%), and the diagnosis was confirmed using tissues in 10 cases (34.5%) and including cytology 13 cases (44.8%). In contrast, in the present study, tissue samples were available for 54 (94.7%) of 57 EBUS-TBNA cases using EchoTip ProCore®, and a definitive diagnosis was obtained for 50 (87.7%) cases. A definite diagnosis was made for 30/31 (97%) lung cancer cases; a diagnosis was obtained for each of the 31 cases. Although there was a difference between the number of cases that underwent EBUS-TBNA before and after the introduction of EchoTip ProCore® (13.5 and 20.7 cases/year, respectively), there was no significant increase or decrease in the number of bronchoscopies in our hospital, suggesting an improvement in the tissue diagnosis rate after the introduction of EchoTip ProCore®. Therefore, the introduction of EchoTip ProCore® contributed to more accurate diagnoses. Three of 31 lung cancer cases were difficult to diagnose because of peripheral lesions that could not be pathologically diagnosed, and EBUS-TBNA was successfully used for tissue diagnosis. From this evidence, the diagnostic rate of EchoTip ProCore® is superior to that of EBUS-TBNA using a standard needle. Regarding safety, only one of 57 patients who had punctured a cyst received prophylactic antimicrobials after EBUS-TBNA. None of the patients developed mediastinitis, and only one case of suspected sarcoidosis with BAL developed pneumonia after bronchoscopy, probably owing to BAL, which was positive for the pneumococcal urinary antigen and was relieved by oral levofloxacin treatment. No other complications were observed. The incidence of complications after EBUS-TBNA has been reported to be 0.15% to 0.46% 18, 19, and EchoTip ProCore® was safe as it did not increase the incidence of complications. Furthermore, several studies have reported that samples obtained using EBUS-TBNA as a cell block can allow PD-L1 staining 20, 21. The present study shows that EBUS-TBNA with EchoTip ProCore® can consistently yield large tissues suitable for direct immunostaining of PD-L1 (Figure 3). Additionally, in one patient, Oncomine™ Dx. Target Test, which is the first FDA-approved next-generation sequencing-based companion diagnostic method for diagnosing EGFR mutation, ALK rearrangement, ROS1 rearrangement, and BRAF V600E mutation in patients with NSCLC, was performed without complications using our methods. Specifically, EBUS-TBNA with EchoTip ProCore® can collect appropriate samples for next-generation sequencing examinations. Among 22 patients with NSCLC who could yield histological specimens, the PD-L1 TPS was successfully examined in 19 patients except for one patient for staging reasons, one for differentiation between breast and lung cancer recurrence, and one for T790M search purposes. This high success rate could contribute to the selection of more appropriate individual therapy for patients with NSCLC.

This study had some limitations. First, it was difficult to puncture small lymph nodes with EchoTip ProCore® given its side core. Second, this was a small uncontrolled study, a single-center study and did not perform comparisons with other needles. However, as shown in Figure 2, this needle allowed us to consistently obtain large tissue samples. Finally, it was unclear whether the superior diagnostic rate was attributed to the slow-pull technique or EchoTip ProCore®. Although examples are not shown, we attempted EBUS-TBNA in a small number of patients at our institution with the slow-pull technique using the 22-gauge Vizishot2 needle (Olympus, Tokyo, Japan). However, tissue specimen collection was not as stable as with EchoTip ProCore®. This indicates that the slow-pull technique using EchoTip ProCore® may be more important.

In conclusion, our method allowed pathological diagnosis of 54 of 57 patients using histology, cytology, or both. The PD-L1 TPS was successfully examined in all 19 patients with NSCLC who could yield histological specimens and required examination. Additionally, none of the patients had complications. Among 13 patients with inadequate specimens or without malignancy, only one patient was subsequently diagnosed as having malignancy with a median follow-up period of 300 days. Therefore, EBUS-TBNA using a puncture needle with a side trap should be considered for patients with hilar and mediastinal lymphadenopathy in routine clinical practice.

Declarations

Guarantor statement

K.M. had full access to all of the data in this reserch, take responsibility for the integrity of the data and the accuracy of the data analysis.

Author contributions

K.M., H.O., are responsible for the study concept and design.

All authors contributed to the acquisition, analysis, or interpretation of data. All authors contributed to the drafting of the manuscript. All authors contributed to the intellectual content. The authors meet criteria for authorship as recommended by the International Committee of Medical Journal Editors Author contributions.

Founding

This research did not receive any specific grant from funding agencies in the public, commercial, or not-forprofit sectors.

Competing interests

The authors declare no conflicts of interest associated with this manuscript.

Correspondence and requests for materials should be addressed to K.M.

References

1- Okamoto H, et al. Endobronchial ultrasonography for mediastinal and hilar lymph node metastases of lung cancer. Chest. 121, 1498-1506 (2002).

2- Yasufuku K, et al. Real-time endobronchial ultrasound-guided transbronchial needle aspiration of mediastinal and hilar lymph nodes. Chest.126, 122-128 (2004).

3- Medford AR, Bennett JA, Free CM & Agrawal S. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA): applications in chest disease. Respirology.15, 71-79 (2010).

4- Dincer HE, Andrade R, Zamora F & Podgaetz E. A new needle on the block: EchoTip ProCore endobronchial ultrasound needle. Med Devices (Auckl).9, 467-473 (2016).

5- Nakai Y, et al. Slow pull versus suction in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid masses. Dig Dis Sci. 59, 1578-1585 (2014).

6- Paik WH, et al. Prospective evaluation of new 22 gauge endoscopic ultrasound core needle using capillary sampling with stylet slow-pull technique for intra-abdominal solid masses. J Clin Gastroenterol.49, 199-205 (2015).

7- Lee JM, et al. Slow-pull using a fanning technique is more useful than the standard suction technique in EUS-guided fine needle aspiration in pancreatic masses. Gut Liver.12, 360-366 (2018).

8- Inoue T, et al. Assessment of factors affecting the usefulness and diagnostic yield of core biopsy needles with a side hole in endoscopic ultrasound-guided fine-needle aspiration. Gut Liver. 10, 51-57 (2016).

9- Bang JY & Varadarajulu S. Procore and flexible 19 gauge needle can replace trucut biopsy needle? Clin Endosc. 46, 503-505 (2013).

10- Yasufuku K, et al. A prospective controlled trial of endobronchial ultrasound-guided transbronchial needle aspiration compared with mediastinoscopy for mediastinal lymph node staging of lung cancer. J Thorac Cardiovasc Surg.142, 1393-1400 (2011).

11- Mitsudomi T, et al. Gefitinib versus cisplatin plus docetaxel in patients with non-small-cell lung cancer harbouring mutations of the epidermal growth factor receptor(WJTOG3405): an open label, randomised phase 3 trial. Lancet Oncol. 11, 121-128 (2010).

12- Solomon BJ, et al. First-line crizotinib versus chemotherapy in ALK-positive lung cancer. N Engl J Med. 371, 2167-2177 (2014).

13- Hida T, et al. Alectinib versus crizotinib in patients with ALK-positive non-small-cell lung cancer(J-ALEX): an open-label, randomised phase 3 trial. Lancet. 390, 29-39 (2017).

14- Reck M, et al. Pembrolizumab versus Chemotherapy for PD-L1-Positive Non-Small-Cell Lung Cancer. N Engl J Med. 375, 1823-1833 (2016).

15- Mok TSK, et al. Pembrolizumab versus chemotherapy for previously untreated, PD-L1-expressing, locally advanced or metastatic non-small-cell lung cancer(KEYNOTE-042): a randomised, open-label, controlled, phase 3 trial. Lancet. 393, 1819-1830 (2019).

16- Brahmer J, et al. Nivolumab versus docetaxel in Advanced squamous-Cell Non-Small-Cell Lung Cancer. N Engl J Med. 373, 123-135 (2015).

17- Borghaei H, et al. Nivolumab versus docetaxel in Advanced nonsquamous Non-Small-Cell Lung Cancer. N Engl J Med. 373, 1627-1639 (2015).

18- Gu P, Zhao YZ, Jiang LY, Zhang W, Xin Y & Han BH. Endobronchial ultrasound-guided transbronchial needle aspiration for staging of lung cancer: a systematic review and meta-analysis. Eur J Cancer. 45, 1389-1396 (2009).

19- Asano F, et al. Deaths and complications associated with respiratory endoscopy: a survey by the Japan Society for Respiratory Endoscopy in 2010. Respirology. 17, 478-485 (2012).

20- Sapalidis K, et al. EBUS-TNBA 22G samples: comparison of PD-L1 expression between DAKO and BIOCARE®. J Cancer. 10, 4739-4746 (2019).

21- Heymann JJ, et al. PD-L1 expression in non-small cell lung carcinoma: comparison among cytology, small biopsy, and surgical resection specimens. Cancer Cytopathol. 125, 896-907 (2017).

Tables

Table 1: Patients characteristics

Baseline demographic and clinical characteristics of 57 patients who underwent EBUS-TBNA with EchoTip ProCore® between June 2017 and February 2020.

N57

N

(%)

age, yr (Range)

71 (18-89)

 

sex

 

 

male

44

77.2

female

13

22.8

punctured lymph nodes

   

#2R

1

1.7

#4R

20

33.3

#4L

3

5.3

#7

26

43.3

#11s

4

6.7

#11i

2

3.3

#11L

2

3.3

right upper lobe

1

1.7

pleural mass

1

1.7

median maximum diameter

   

mm (Range)

27 (14-70)

 

EchoTip ProCore

   

22G

51

89.5

25G

6

10.5

 

Table 2: Pathological diagnosis

Pathological findings of tissue or cytological specimen obtained using EBUS-TBNA.

 

N

(%)

NSCLC

22

38.6

SCLC

8

14

RCC (metastasis)

3

5.3

CUPSq

2

3.5

NET(G2) reccurence

1

1.8

lymphoma

2

3.5

thymoma recurrence

1

1.8

sarcoidosis

4

7

necrotic tissue

1

1.8

tuberculosis

1

1.8

non-malignancy

9

15.8

cyst

1

1.8

inadequate

2

3.5

 

 

N

(%)

classV

31

54.4

classIII

8

14

classII

4

7

classI

14

24.6

NSCLC: non-small cell lung cancer, SCLC: small cell lung cancer, RCC: renal cell cancer, CUP: cancer of unknown primary, NET: neuroendocrine tumor, Sq: squamous cell carcinoma

 

Table 3: PD-L1 status of NSCLC

PD-L1 status non-small cell lung cancer was examined through IHC using the PD-L1 IHC 22C3 PharmDx “dako.”

PD-L1 (TPS)

N

(%)

50%>

8

42

1-49%

5

26

1%<

6

32

TPS: tumor proportion score