Accuracy of Laboratory Tests Drawn by Pull-push Method from Central Venous Catheterization After Routine Flushing with 10 ml Normal Saline.

DOI: https://doi.org/10.21203/rs.3.rs-267380/v1

Abstract

Background: Central venous catheterization (CVC) remains a common practice in the emergency setting. Routine flushing 10 - 20 ml of normal saline to maintain the patency of CVC could affect the accuracy of laboratory tests. Typically, physicians require peripheral vein phlebotomy when more blood sampling is needed. One of the alternative methods, the Pull-push method, could avoid too much pain and unnecessary peripheral vein phlebotomy. However, there has been no recent study analyzing the accuracy of blood sampling using this technique.

Objective: We evaluate laboratory tests' accuracy between blood samples drawn by the Pull-push method from CVC after routine flushing with 10 ml of normal saline versus control.

Methods: We conducted a diagnostic accuracy study from May to September 2019. After exclusion, 72 patients were eligible for analysis. Promptly after central venous catheterization, we drew blood samples, stored them in blood collecting tubes, and labeled them for the gold standard group. We flushed with 10 ml of normal saline before blood sampling using the Pull-push method's completed three times; then, we drew blood samples again, labeled Pull-push group. We compared the laboratory results between two groups by paired t-test. The accuracies were analyzed based on an allowable error by Clinical Laboratory Improvement Amendments (CLIA) and presented by a modified Bland-Altman plot.

Results: The 72 patients were primarily male (n=47, 65.3%), had a mean age 60.1±14.0 years, and were diagnosed with sepsis (n=4, 5.6%) or septic shock (n=65, 90.3%). For almost all the laboratory values, including hemoglobin, hematocrit, white blood cell count, platelet count, blood urea nitrogen, creatinine, sodium, potassium, chloride, bicarbonate, prothrombin time, international normalized ratio, and blood sugar, the accuracy was more than 90% (92.8-98.6%), except aPTT (85.5%) and aPTT ratio (86.7%) 

Conclusion: Laboratory tests drawn by the Pull-push method could replace peripheral vein phlebotomy to avoid too much pain and infection risk.

1. Introduction

Central venous catheterization remains a standard procedure in the emergency department. After the procedure, it is mandatory to flush the saline 10-20 ml to prevent clot formation in central venous catheters (CVC). However, physicians usually request other blood samples in critically ill patients. Patients need to be re-drawn from peripheral blood, which is sometimes tricky owing to collapsed arteries due to shock. Patients may get too much pain from multiple punctures, and their veins may become ruptured or get inflammatory complications 1.

From the above problem, therefore, many previous studies have been conducted to reduce unnecessary blood venipuncture. Patients with a peripherally inserted central catheter (PICC), tunneled catheter, or permanent catheter were summarized as follows: 1) Discard method 1-3 by draw blood (waste volume): the volume depends on the dead space of each catheter. After waste volume discard, physicians then collect blood samples for a laboratory test. However, this method may affect the patient's hemodynamic, especially patients with anemia due to blood loss. 2) Reinfusion method 4 by drawing waste volume and holding blood samples for testing: the waste volume is then returned to the patient. The limitation is that the clotting-initiated blood may be returned to the patient 5 and may increase the chance of infection 6. 3) Push-Pull method 7: the method is to push-pull blood in and out approximately three times in pediatric patients with permanent catheters for chemotherapy. The study said that the laboratory results were accurate compared with the Discard method to reduce blood loss. Moreover, the Push-Pull method can maintain the circulatory system's stability and reduce the problem of infection. However, no such studies have been conducted in the emergency department for CVC patients. We investigate the accuracy of laboratory results by the Pull-push method compared with control in CVC-treated patients.

2. Materials & Methods

2.1. Patients and setting

We conducted a diagnostic accuracy study at the Department of Emergency Medicine, Lampang Hospital, Thailand, from May 2019 to September 2019. Patients who were older than 18 years of age with indication and no contraindications for CVC were enrolled. We obtained CVC via right internal jugular catheterization. All participants signed informed consent before enrollment. We excluded: 1) patients who refused to participate, 2) pregnant women, 3) technical errors such as blood clots or hemolysis, and 4) patients with immediate complications such as pneumothorax.

The CVC surgical equipment is all the same make and model, with a 16/16-gauge double lumen, locking both lumens to prevent air from entering. Furthermore, for blood samples' accuracy in this study's gold standard group, normal saline was not pre-cast in the CVC line. However, all patients were in Trendelenburg's position to prevent air embolism 8.

We cleaned the skin with the same 2% chlorhexidine-gluconate in 70% alcohol solution without povidone-iodine in every case before the procedure. Studies have shown that povidone-iodine may distort laboratory results 9, and 2% chlorhexidine-gluconate in 70% alcohol solution may better reduce infection 10.

After successful CVC insertion, we collected 12 ml of blood samples in the control group. The samples were then placed in blood collecting tubes, sorted according to Clinical Laboratory Improvement Amendments (CLIA) guidelines 11 labeled as a gold standard group. We flushed the line with normal saline 10 ml and used an empty syringe (10 ml empty syringe) to perform three pull-push sessions. The pull-push session included slowly pulling 10 ml blood from the line for 5 seconds duration, then gently pushing the 10 ml of blood back into the line for 5 seconds duration, and then waiting for 5 seconds before beginning the next pull-push session. We used another empty syringe to collect 12 ml blood samples and labeled them as a Pull-push group. The time from both groups of blood samples was collected until the packaging was completed for less than 3 minutes to control the environment close to the same, reduce various external influences as much as possible, and perform the laboratory results simultaneously.

The study followed through in agreement with the Declaration of Helsinki (2008) of the World Medical Association. Patient management pursued the standard of the Human Research Ethics Committee, Lampang Hospital. The Ethics Committee approved the study on 5th February 2016 (EC approval No. 19/2559).

Definition12

  1. Percentage error (% error): the error of the laboratory tests from the Pull-push group was compared with the gold standard using the equation:

(laboratory test results from the Pull-push group — the gold standard) x 100

laboratory test results from the gold standard

  1. Allowable error (%): the acceptable percentage errors as defined by the CLIA [13, 14]:

Prothrombin time (PT): ±15%;

International normalized ratio (INR): ±15%;

Activated partial thromboplastin time (aPTT): ±15%;

aPTT ratio: ±15%;

Hemoglobin (Hb): ±7%;

Hematocrit (Hct): ±6%;

White blood cell (WBC): ±15%;

Platelet count: ±25%;

Blood urea nitrogen (BUN): ±9%;

Creatinine (Cr): ±15%.

Sodium (Na): ±4 mmol/L;

Potassium (K): ±0.5 mmol/L;

Chloride (Cl): ±5%;

Bicarbonate (HCO3): ±20%; and

Blood sugar (BS): ±10%.

  1. Accuracy (%): The percentage of allowable error for each laboratory test. Accuracy ≥ 90% is considered highly accurate. 

2.2. Study size estimation

Based on the pilot study, the mean hemoglobin of the Pull-push group and gold standard group was 8.8±2.7 vs. 9.7±2.7 gm/dL. To obtain the power of 80%, an alpha error of 5%, with a two-sided test, this study required at least 72 patients to validate the various laboratory tests.

2.3. Safety protocols

  1. The operative doctor must be a senior emergency medicine resident under the supervision of a medical instructor
  2. All patients needed a pulse oximeter, electrocardiogram, and blood pressure monitoring for safety.
  3. If complications might occur, Patients would immediately get care. Patients and relatives would get notified and excluded from the study.
  4. We monitored the complications on days 1, 2, and 7 after the procedure.

2.4. Statistical analysis

Baseline characteristics were presented by number (percentage) for categorical data and by mean±SD for numerical data. The mean value of laboratory tests between the Pull-push group and the gold standard group were compared using paired t-tests, with laboratory tests having a p-value of >0.05 being interpreted as insignificant. Mean difference and percentage error were also analyzed and presented using modified Bland-Altman plots. We calculated the accuracy for each laboratory test according to the CLIA standard. 

3. Results

From May to September 2019, 73 patients met the study criteria. After exclusion (n=1, 1.4%), 72 remaining patients were eligible for analysis (Fig 1).

Most of the patients were male, mean age 60.1 ± 14.0 years, almost all were diagnosed with sepsis and septic shock (Table 1).

3.1. Mean values, mean differences, and percentage errors.

The mean differences of laboratory tests varied from -0.2 ± 1.0 to 1.1 ± 2.6 units. The mean of laboratory results by the Pull-push method and gold standard group were not different except for coagulogram (PT, INR, aPTT, aPTT ratio. ) (Table 2).

The percentage errors of laboratory tests were presented by modified Bland-Altman plots, complete blood count (Fig 2), electrolytes, blood sugar (Fig 3), and coagulogram (Fig 4), which were all in the allowable error range except aPTT and aPTT ratio. 

3.2 The accuracy

When analyzing accuracy based on CLIA's allowable error criteria 13,14, we found that laboratory results using the Pull-push method were very accurate. (92.8% -98.6%) except aPTT (85.5%), and aPTT ratio (86.7%). (Table 2)

4. Discussion

For patients undergoing CVC with the right internal jugular vein after flush normal saline 10 ml in routine practice, almost all laboratory results show very high accuracy with three Pull-push methods (92.8% -98.6%). The laboratory with high accuracy results includes Hb, Hct, WBC, platelet count, BUN, Cr, Na, Cl, K, HCO3, PT, INR, and blood sugar. The errors seem to be high in aPTT and its ratio. However, those errors are still within the allowable range. According to CLIA standards 13,14, this study's results are beneficial in critically ill patients. Physicians may avoid unnecessary blood drawing from peripheral lines. On average, physicians need to draw blood samples from the peripheral lines 6-8 times in a single patient. Moreover, patients are in shock with flattened venous stenosis leading to difficulty in drawing blood.

Physicians previously recognized the Discard method 1-3 as having the same accuracy as standard. However, to avoid unnecessary blood loss (waste volume) from the Discard method, physicians usually re-infuse the waste blood back into the central lines 4. This re-infusion may increase the risk of infection and may mistakenly return blood clots to the patient. In our study, the Pull-push method 7, using an empty syringe of 10 ml to pull the blood in and out three times, is safe for most patients. The patient's vital signs remain stable with the Pull-push method.

In contrast to our study, the patients in other previous Pull-push methods are mostly cancer patients. They all aimed to study coagulation tests' accuracy 1-3 to evaluate safety before invasive procedures, monitor and follow up treatment. There are lacking studies on critically ill patients in the emergency department or intensive care unit 15.

From systematic reviews of 11 studies 16, they find that sample sizes in each study were too small (N range from 12-53) (72 sample sizes in this study). Pearson correlations, or mean difference comparisons, may have statistical differences but cannot be interpreted as clinical judgment, making them difficult to apply in real practice. In our study, allowable errors are corrected mainly by reference to CLIA 13,14.

Serum potassium is the most vulnerable one. CLIA uses a different error to justify serum potassium accuracy instead of a percent error as usual. Therefore, serum potassium has a very narrow acceptable difference. The serum potassium difference needs to be not greater than ± 0.5 mmol / L to become acceptable. Our study shows that serum potassium with the Pull-push method is still accurate at 95.8%. This high accuracy in such a vulnerable laboratory gives confidentiality to the Pull-push method in other laboratory subtypes.

The aPTT and its ratio have a low accuracy of only 85.5% and 86.7%, respectively. Compared to other coagulograms such as PT and INR, the accuracy is as high as 98.1% and 97.1%, respectively. Fortunately, PT and INR are more useful than aPTT in an emergency setting, such as stroke, sepsis, and accident. The low accuracy of aPTT and its ratio should not impact much to routine clinical practice. Further study may help to answer whether this low accuracy may prevent using the Pull-push method in aPTT.

Our study highlights the use of control group blood samples drawn from the same CVC line before flushing normal saline 10 ml, then the Pull-push method, which is consistent with routine clinical practice. Our study design has an advantage over other studies using blood samples from peripheral phlebotomy as a control, where the values are significantly different 2,3,15,17.

5. Conclusions

Laboratory tests drawn by the CVC line's Pull-push method could replace peripheral vein phlebotomy to reduce too much patients' pain and risk of infection.

Declarations

Author contributions

TL contributed to the conception and design of the work, data collection, and drafting of the article; CS contributed to data collection; JP contributed to data collection and drafting of the article; SM contributed to the conception, drafting, and critical revision of the article, and gave final approval.

Acknowledgment

The authors wished to thank all emergency nurses and laboratory officers of Lampang Hospital.

This work is supported by the Excellence Center in Stroke, Thammasat University.

Funding

None

Competing interests

The authors declare no competing interests.

References

  1. Rondina MT, Markewitz B, Kling SJ, Nohavec R, Rodgers GM. The accuracy of activated partial thromboplastin times when drawn through a peripherally inserted central catheter. American Journal of Hematology 2007;82:738-9.
  2. Mayo DJ, Dimond EP, Kramer W, Horne MK. Discard volumes necessary for clinically useful coagulation studies from heparinized Hickman catheters. Oncol Nurs Forum 1996;23:671-5.
  3. Humphries L, Baldwin KM, Clark KL, Tenuta V, Brumley K. A Comparison of Coagulation Study Results Between Heparinized Peripherally Inserted Central Catheters and Venipunctures. Clinical Nurse Specialist 2012;26:310-6.
  4. Dech ZF, Szaflarski NL. Nursing Strategies to Minimize Blood Loss Associated With Phlebotomy. AACN Advanced Critical Care 1996;7:277-87.
  5. Cosca PA, Smith S, Chatfield S, et al. Reinfusion of discard blood from venous access devices. Oncol Nurs Forum 1998;25:1073-6.
  6. Hinds PS, Wentz T, Hughes W, et al. An Investigation of the Safety of the Blood Reinfusion Step Used With Tunneled Venous Access Devices in Children With Cancer. Journal of Pediatric Oncology Nursing 1991;8:159-64.
  7. Adlard K. Examining the Push—Pull Method of Blood Sampling From Central Venous Access Devices. Journal of Pediatric Oncology Nursing 2008;25:200-7.
  8. Graham AS, Ozment C, Tegtmeyer K, Lai S, Braner DA. Central venous catheterization. N Engl J Med 2007;356:e21.
  9. Van Steirteghem A, Young D. Povidone-iodine (" Betadine") disinfectant as a source of error. Clinical chemistry 1977;23:1512-.
  10. Organization WH. WHO guidelines on drawing blood: best practices in phlebotomy: World Health Organization; 2010.
  11. Adcock DM. Collection, transport, and processing of blood specimes for testing plasma-based coagulation assays and molecular hemostasis assays: approved guideline: CLSI; 2008.
  12. Lokeskrawee T, Muengtaweepongsa S, Inbunleng P, Phinyo P, Patumanond J. Accuracy of laboratory tests collected at referring hospitals versus tertiary care hospitals for acute stroke patients. PLOS ONE 2019;14:e0214874.
  13. Data Innovations. at https://datainnovations.com/allowable-total-error-table.)
  14. Westgard JO, Westgard SA. The Quality of Laboratory Testing Today. American Journal of Clinical Pathology 2006;125:343-54.
  15. Lin RZ-K, Dise CA. Venous access devices: Obtaining coagulation tests in adult inpatients with cancer. Clinical journal of oncology nursing 2009;13:347.
  16. Dalton KA, Julia Aucoin D, Britt Meyer M. Obtaining coagulation blood samples from central venous access devices: a review of the literature. Clinical journal of oncology nursing 2015;19:418.
  17. Pinto KM. Accuracy of coagulation values obtained from a heparinized central venous catheter. Oncol Nurs Forum 1994;21:573-5.

Tables

Due to technical limitations, tables are only available as a download in the Supplemental Files section.