Correlation Analysis for the Selection of Microtitanium Plates with Different Specifications for use in a Cervical Vertebral Dome Expansion Laminoplasty

DOI: https://doi.org/10.21203/rs.3.rs-28336/v1

Abstract

Backgrounds: Cervical vertebral dome expansion laminoplasty is a new surgical method for the treatment of cervical spondylosis. We analyzed correlations between the selection of microtitanium plates with different specifications for use in a cervical vertebral dome expansion laminoplasty to establish guidance for the selection of suitable microtitanium plates.

Methods: Sixteen patients that underwent the new, full lamina posterior spinal canal enlargement with a cervical spinal stenosis angioplasty procedure for treatment of their cervical spinal cords were recruited at our hospital. From February 2017-September 2018, medical records confirmed that all patients underwent cervical CT and MRI tests pre- and postsurgery. The anteroposterior diameter of the spinal canal, changes in the cross-sectional area of the spinal canal, and the pre- and postsurgery distance of the cervical spinal cord after applying microtitanium plates with different lengths were measured by Mimics version 17.0 software. A statistical regression and correlation analysis of relevant specification parameters of the microtitanium plate was then studied.

Results: As the size of the microtitanium plate increased, we found that the cross-sectional area of cervical spinal canal and distance between the descendants of the lamina and the distance of cervical spinal cord concordantly increased. The regression equation associated with sagittal diameter, cross-sectional area, and posterior movement distance of the cervical spinal cord was obtained.

Conclusions: The use of the corresponding regression equations enabled the prediction of the cervical spinal canal parameters and posterior movement distance of the cervical spinal cord when adopting different specifications of the microtitanium plate for different segments of the cervical vertebrae. This analysis guided the selection of microtitanium plates with appropriate specifications for different cervical vertebrae in a cervical vertebral dome expansion laminoplasty.

Full Text

This preprint is available for download as a PDF.