Background: A need for improved, cassette-based automation of 61Cu separation from irradiated Ni targets was identified given the growing interest in theranostics and generally lengthy separation chemistries for 64Cu/64Ni, upon which 61Cu chemistry is often based.
Methods: A method for separating 61Cu from irradiated natNi targets was therefore developed, with provision for target recycling. Following deuteron irradiation, electroplated natNi targets were remotely transferred from the cyclotron and dissolved in acid. The dissolved target solution was then transferred to an automated FASTlab chemistry module, where sequential TBP and TK201 (Triskem) resins isolated the [61Cu]CuCl2, removed Ni, Co, and Fe, and concentrated the product into a formulation suitable for anticipated radiolabelling reactions.
Results: 61Cu saturation yields of 190 ± 33 MBq/µA from energetically thick natNi targets were measured. The average, decay-corrected, activity-based dissolution efficiency was 97.5 ± 1.4 % with an average radiochemical yield of 90.4 ± 3.2 % (N = 5). The isolated activity was collected approximately 65 minutes post end of bombardment in ~2 mL of 0.06 M HCl (HCl concentration was verified by titration). Quality control of the isolated [61Cu]CuCl2 (N = 5) measured 58Co content of (8.3 ± 0.6) × 10-5 % vs. 61Cu by activity, Ni separation factors ≥ (2.2 ± 1.8) × 106, EoB molar activities 85 ± 23 GBq/µmol and NOTA-based EoB apparent molar activities of 31 ± 8 MBq/nmol and 201 MBq/nmol for the 30 min and 3.3 h (N = 1) irradiations, respectively.
Conclusion: High purity 61Cu was produced with the developed automated method using a single-use, cassette-based approach. It was also applicable for 64Cu, as demonstrated with a single proof-of-concept 64Ni target production run.