3.1 Characterization of SSBC/ZVI composite
In order to characterize the characteristics of SSBC/ZBI composite filler and identify the mechanism of pollutant removal, fresh and used SSBC/ZVI composite was characterized by SEM-EDX, FT-IR, XRD and specific surface area analysis. The results and discussion about the characterization of materials were presented as follows.
3.1.1 SEM-EDX characterization
The microstructure of fresh SSBC/ZBI composite with 200 and 10000 times magnifications was presented in the SEM results in Fig. 1a. It can be found that the filler surface was heterogeneous due to the inconsistency of the particle size and density of the raw materials. The lamellar structure with relative smooth surface and short rod crystal pieces should be assigned to ferron particles and ATP, respectively. Previous research suggested that the surface of Fe0 in the fresh Fe-C micro-electrolytic filler is relatively smooth [15]. The ATP acts as the adhesive is short rod with 2 µm in length and about 100 nm in diameter [16]. The rest amorphous material of the filler which contains rough, irregular structures with very few pores is SSBC [17]. EDX element contents analysis (shown in Fig. 1b) made clear to us that the filler contains iron, carbon and oxygen derived from the organic matter of SS, aluminum and potassium derived from the inorganic components of SS, and magnesium, silicon, and oxygen in ATP. Approximately, 32.15% iron and 13.56% carbon were measured in the SSBC/ZVI composites by EDX.
3.1.2 FT-IR characterization
FT-IR characterization was conducted to obtain the chemical structure and functional groups information of SSBC/ZVI composite, and the result was presented in Fig. 1c. The strong peak at about 3437 cm− 1 was caused by O-H stretching vibration [18]. The peak at 1632 cm− 1 was preferentially assigned to the C = O stretching vibration of carbonyl groups. The peak at 1063 cm− 1 was probably caused by C-O-C stretching vibrations. The broad band at about 1035 cm− 1 was mainly related to C–O stretching vibration [19]. The weak peak at 770 cm− 1 was probably associated with C-H bending vibration, while the peak at 779 cm− 1 was correspond to the stretching vibration of aromatic C–H groups [20]. Diversity of functional groups explains that SSBC and SSBC/ZVI can be used as adsorbent for multiple pollutants removal.
3.1.3 XRD characterization
XRD characterization was conducted to investigate the crystal structures of Fe0 and carbon on the surface of SSBC/ZVI composites. As the results shown in Fig. 1d, the SSBC/ZVI showed obvious peaks at 2θ of 44.9°, which corresponds to the reflection of Fe0 [21]. The weak bands at 2θ of 25.9°indicated the carbonaceous structure presented in SSBC/ZVI [22]. The diffraction peaks of SiO2 were often appeared in SSBC as previous reports [23]. XRD analysis showed that SiO2 existed in both SSBC and SSBC/ZVI, and their content and morphology remained relatively stable.
3.1.4 Specific surface area analysis
The evolution of the BET surface area of SSBC/ZVI filler can be observed in Table 2. As can be seen, the BET surface area of fresh SSBC/ZVI was 32.35 m2‧g− 1, indicating the development of pores at the stage of carbonization and filler calcination. However, the BET surface area was smaller than commercially available Fe-C filler (165.638 m2‧g− 1) [24], which was due to the relative low specific surface area of SSBC [25].
Table 2
BET surface area and pore structure parameter of micro-electrolysis filler
Samples
|
SBET
|
Vtotal (cm− 3‧g− 1)
|
Daverage (nm)
|
SSBC a
|
39.40
|
0.08
|
10.32
|
Fresh SSBC/ZVI b
|
32.35
|
0.121
|
16.65
|
a Sewage sludge bio-char, b Sewage sludge bio-char/ zero valent iron composite. |
3.2 Evaluation of CSPW treatment effect under different condition
The pollutants removal efficiency of micro-electrolysis was closely related to operation conditions, such as reaction time, initial pH, filler dosage In this study, hydraulic retention time (HRT), initial pH, and filler dosage were chosen as operational factors to discuss their influences on COD removal efficiency, and the results were illustrated in Fig. 2.
3.2.1 Pollutants removal efficacy with different HRT
HRT determines the reaction time of micro-electrolysis, and the influence of HRT on COD removal efficiency of CSPW was depicted in Fig. 2a. The COD remove process could be divided into three stages. In the first stage (0–20 min), 15.2% of COD was removed within the 20 min and the COD removal rate was much higher than the residual two stages, which was due to the porous structure of SSBC/ZVI composite could adsorb the pollutants on its surface [26]. In the second stage (20–120 min), the growth of COD removal efficiency slowed down gradually. On the one hand, the adsorption capacity of SSBC/ZVI filler was limited, and the pollutants absorbed on the filler surface made a mass transfer resistance of electrons [5]. On the other hand, Fe2+ released in the anode might gathered on the filler surface, which further increased the mass transfer resistance [12]. In the third stage (120–180 min), the COD removal efficiency kept at relative constant value. As the reaction time extended, the pH value of the reaction system will rise to neutral or even alkaline. The micro-electrolysis reaction will halt at the neutral or alkaline condition due to the precipitated iron in the form of hydroxides attached on the filling surface, and the accessibility of active [H] and ‧OH will decrease. Base on the results above, a satisfied COD removal efficiency (30.5%) can be achieved at HRT of 2 h.
3.2.2 Pollutants removal efficacy under different initial pH condition
The pH value can affect the availability of active [H] and ‧OH in the reaction system, which in turn affects the pollutants removal efficiency by iron-carbon micro-electrolysis. Five different pH levels (1, 3, 5, 7 and 9) with HRT of 2 h and filler dosage of 100 g/L were other condition, were operated to survey COD removal efficiency in batch experiments. The influence of pH on the pollutants removal efficiency was illustrated in Fig. 2b. With the increase of the pH from 1 to 3, COD removal efficiency was marginally increased from 24.6–26.7%. When the pH increased from 3 to 9, the COD removal efficiency decreased gradually from 26.7–3.0%. The micro-electrolysis was acid promoted reaction and mainly occurred between anode and cathode materials with the electron transfer. During the micro-electrolysis, the Fe0 was gradually corroded under the acid condition with electron lose. The electron transfer will be enhanced by increasing the H+ concentration and the accessibility of active [H] and ‧OH will be improved [27]. Large amount of Fe2+ will be generated gradually from Fe0 corrosion, and then the precipitate Fe(OH)x will be created as the Fe2+ oxidization and H+ consumption. The iron hydroxides acts as the mass transfer resistance could be dissolved in the acidic condition, resulting in more reactive sites exposed. In neutral or alkaline condition, the micro electrolysis reaction will halt. It was generally accepted that the electron transfer rate would be inhibited remarkably in the alkaline condition, thus the COD removal efficiency continued to decline when the initial pH increased from 3.0 to 9.0. In order to achieve an effective COD removal efficiency, the initial pH of CPSW was adjusted to 3 before treatment.
3.2.3 Pollutants removal efficacy with different SSBC/ZVI filler dosage
The COD removal efficiency under different filler dosage was studied and the results were shown in Fig. 2c. As illustrated in Fig. 2c, COD removal efficiency increased gradually when the filler dosage increased from 50 to 150 g/L, and the maximum COD removal rate of 33.9% was achieved with 150 g/L filler dosage. This could be explained by the increased surface area, reactive sites and [H] formation when the filler dosage increased [27]. Improved pollutants removal rate will be achieved when the electrode materials dosage increased because the pollutants degradation generally occurs at the active sites of the anode surface[28]. However, the pollutant removal efficiency will decrease when the electrode material dosage is too high, as the contacting area between electrode materials particles and wastewater would decrease. Moreover, micro-electrolysis reactions would be weakened when excess iron reacted with H+ [29]. The appropriate dosage of SSBC/ZVI composites was 100 g/L with corresponding COD removal rate of 26.7%.
3.3 Characterization of pollutants removal by GC-MS
To clarify the pollutants degradation pathways, GC-MS analysis was used to examine the pollutants and derived intermediates in CSPW. The pollutants species and derived intermediates in CSPW were listed in Table 3. Total of 17 main organic pollutant species were detected in raw CSPW, which were the major contributors to COD. For the untreated CSPW, 17 main organic pollutants could be divided into 7 types including alcohols (No. 1–5), ketones (No. 6), esters (No. 7–9), intermediate (No. 10), amines (No. 12–15), nitriles (N0. 17) and pyridines(No. 18, 20). After micro-electrolysis treatment for 120 min, the number of main pollutant species increased to 23. Specifically, there was no pollutant species were completely removed and 6 new pollutant species were generated after treatment. The above results suggested that the COD of CSPW could be partially removed owing to the abatement of organic pollutant species in SSBC/ZVI treatment. It was obvious that most pollutants presented in CSPW were degraded into smaller molecules after micro-electrolysis treatments, and the above discoveries supported the COD removal by SSBC/ZVI treatment.
Table 3
Main pollutant species detected by GC-MS before and after micro-electrolysis treatments
No.
|
Organic compounds name
|
Category
|
MW
(g/mol)
|
Peak area (×105)
|
Raw CSPW
|
Treated CSPW
|
1
|
Methanol
|
Alcohols
|
32
|
94.43
|
66.74
|
2
|
Ethanol
|
Alcohols
|
46
|
105.24
|
72.38
|
3
|
Isopropanol
|
Alcohols
|
60
|
59.02
|
35.77
|
4
|
1-Butanol
|
Alcohols
|
74
|
16.61
|
7.59
|
5
|
3-pentanol
|
Alcohols
|
88
|
16.16
|
6.43
|
6
|
Acetone
|
Ketones
|
58
|
23.57
|
10.62
|
7
|
Methyl acetate
|
Esters
|
74
|
7.55
|
2.96
|
8
|
Ethyl acetate
|
Esters
|
88
|
25.12
|
12.18
|
9
|
Methyl acetoacetate
|
Esters
|
116
|
10.82
|
7.24
|
10
|
4-hydroxy-4-methyl-2-pentanone
|
Intermediate
|
116
|
13.99
|
2.89
|
11
|
Formamide
|
Amides
|
45
|
ND
|
2.62
|
12
|
Aminotoluene
|
Amines
|
107
|
4.31
|
1.32
|
13
|
Diisopropylethylamine
|
Amines
|
129
|
55.39
|
10.36
|
14
|
Triethylamine
|
Amines
|
101
|
19.30
|
3.68
|
15
|
N,N-Dimethylformamide
|
Amines
|
73
|
4.55
|
2.08
|
16
|
Ethylamine
|
Amines
|
45
|
ND
|
1.39
|
17
|
Acetonitrile
|
Nitriles
|
41
|
8.27
|
8.14
|
18
|
2,3-Cyclopenteno pyridine
|
Pyridines
|
119
|
7.25
|
3.83
|
19
|
2,6-Lutidine
|
Pyridines
|
107
|
ND
|
2.89
|
20
|
2-Dimethylaminopyridine
|
Pyridines
|
122
|
3.22
|
1.65
|
21
|
2-Aminopyridine
|
Pyridines
|
94
|
ND
|
1.14
|
22
|
p-Nitrotoluene
|
Benzenes
|
137
|
ND
|
2.37
|
23
|
Formic acid
|
Acids
|
60
|
ND
|
7.25
|
3.4 Pollutants removal mechanisms analysis
In order to clarify the pollutants removal mechanism by the SSBC/ZVI micro-electrolysis system, the used SSBC/ZVI filler and iron sludge were characterized by EDX and FTIR firstly, and the results were shown in Fig. 3. The EDX analysis was carried out for used SSBC/ZVI composite to show the change of the filler after CSPW treatment (Fig. 3a). It is shown in EDX spectra that after SCPW treatment, the content of Fe in the composite decreased obviously while the content of carbon increased correspondingly, indicating that a great amount of Fe0 was consumed after micro-electrolysis treatment.
The FTIR analysis of used SSBC/ZVI composite was also conducted to show the change of the filler after CSPW treatment (Fig. 3b). Compared with the FTIR spectrum of fresh SSBC/ZVI (Fig. 1c), several new absorption peaks were found in the FTIR spectrum of used SSBC/ZVI. The peak at 1420 cm− 1 was caused by C = O symmetric stretching vibration. The peak at 1320 cm− 1 corresponds to C–N stretching vibration of amines. In addition, the peak at 1063 cm− 1 covered by the two strong peaks at 1035 cm− 1 and 986 cm− 1. The peak at 986 cm− 1 corresponds to C–O–C vibrations of proteins or polysaccharides. The peak at 689 cm− 1 was ascribed to C–Cl stretching vibration. The peaks at 513 cm− 1 and 472 cm− 1 were associated with M-X (M-metal, X-halogen) stretching vibration. Diversity of functional groups in SSBC/ZVI explains SSBC/ZVI can be utilized for the adsorption removal of multiple pollutants in CSPW. These new absorption peaks in FTIR spectra of SSBC/ZVI indicated that the pollutants in CSPW can be removed through adsorption. In addition, in order to investigate the pollutants removal by SSBC adsorption, separate adsorption experiment was also conducted. The results of adsorption experiments showed that 5.2% of COD could be removed within 2 h under neutral pH conditions and 100 g/L SSBC/ZVI dosage. SSBC/ZVI showed limited adsorption removal rate of pollutants in CSPW due to the low absorption capacity of SSBC [30].
Iron sludge containing the ferrous and ferric hydroxides was formed by oxidation and precipitation of Fe2+ released from anode. Pollutants can be removed by iron sludge with the combinational effects of enmeshment, co-precipitation, adsorption and interparticle bridging in the process of coagulation [13]. FTIR characterization of iron sludge (Fig. 3c) showed that there were some new absorption peaks in addition to the infrared absorption peaks produced by the detrital materials exfoliated from SSBC/ZVI. The new FTIR peak at 3055 cm− 1 caused by the C–H vibration of ethyl and methylene groups suggested that the pollutants with aliphatic chain could be removed by iron sludge flocculation. The new peak at 1617 cm− 1 suggested that compounds containing benzene ring could be also removed by iron sludge flocculation. However, some pollutants may volatilize during the drying process of sample preparation for FTIR characterization and cannot be detected.
Figure 4 proposed the removal mechanisms of pollutants in CSPW treated by SSBC/ZVI micro-electrolysis system. The mechanism of pollutants removal includes the adsorption of SSBC and the coagulation as discussed above, as well as micro-electrolysis [13, 31]. In SSBC/ZVI micro-electrolysis system, SSBC acts as the cathode in which H+ obtain electrons to generate [H] for pollutants reduction. FeO acts as the anode of micro-electrolysis system, and FeO loses electrons to form Fe2+. OH radical formed in anode can oxide the pollutants to intermediates or CO2 and H2O. In terms of newly generated organic species as shown in Table 3, the possible formation pathway can be illustrated as follows. Ethylamine (No. 16) was formed by de-isopropyl and de-ethyl of diisopropylethylamine (No. 13) and triethylamine (No. 14), respectively. Formamide (No. 11) may be an intermediate formed by demethylation of N,N-dimethylformamide (No. 15). 2,6-lutidine (No. 19) may be an intermediate formed by heterocyclic ring opening of 2,3-cyclopenteno pyridine (No. 18). 2-Aminopyridine (No. 21) was formed by the demethylation of 2-Dimethylaminopyridine (No. 20), and p-Nitrotoluene (No. 22) was formed by the reduction of aminotoluene (No. 12).
3.5 Reusability of SSBC/ZVI composite filler
Previous researches reported that the micro electrolysis fillers can be gradually hardened after the repeated running process owing to the passivation, blockage, and mass transport limitation of the filler surface [5, 32]. Long-term run of SSBC/ZVI system for CSPW treatment was conducted to verify whether the fillers could become harden. The operation conditions for 6 runs within 720 min were set as follows with the initial pH of 3, HRT of 2 h, filler dosage of 100 g/L. The COD removal efficiency and BI values were presented in Fig. 5. The COD removal efficiency in SSBC/ZVI was stable and performed well within the first 5 runs. While for the sixth run, COD removal efficiency decreased gradually from 29.1 to 23.9%, owing to the surface passivation, blockage, and mass transport limitation. The results suggested that SSBC/ZVI systems had relative high stability and excellent reusability for COD removal from CSPW. The COD of SSBC/ZVI treated CSPW was still high and the effluent cannot be discharged directly. We explore the feasibility using SSBC/ZVI as pretreatment technology before biochemical treatment, since micro-electrolysis pretreatment could increase the BI value of wastewater, which is helpful for subsequent biological processes [33]. The BI value is normally used to express the biodegradability of wastewater. When BI value is higher than 0.3, the wastewater usually exhibits a better biodegradability [34]. The BI values after different operation runs were analyzed and the results were shown in Fig. 5. Raw CSPW cannot be biodegraded according to the low BI value of 0.17. Improvement in biodegradability was achieved with SSBC/ZVI micro electrolysis system in the first 4 run operation, and BI value increased from initial 0.17 to 0.39, 0.36, 0.36 and 0.32, respectively. The results indicated the biodegradability of SSBC/ZVI system treated CSPW was enhanced. However, the BI value decreased to 0.29 and 0.27 after the 5th and 6th run operation. Therefore, after 4 run operation using SSBC/ZVI for CSPW pretreatment, necessary measures should be taken to ensure the stability of the system.
3.6 Comparison of different pretreatments of CSPW for biodegradability improvement
Table 4 shows a comparison of different advanced oxidation processes (AOPs) as pretreatment methods of real chemical synthesis-based pharmaceutical wastewater, which mainly includes ozone oxidation, inner electrolysis, Fenton oxidation, catalytic oxidation and the combination technologies. The pretreatment effect of SSBC/ZVI system on real pharmaceutical wastewater is equivalent to the reported methods such as CoMnAl-CMO-Al2O3/H2O2 oxides catalyst process [35], microwave assisted Fenton like process [36], but higher than the process using an Fe2O3 / SBA-15 nano composite catalyst [37]. It should be emphasized that the raw material of SSBC/ZVI composites filler is waste sewage sludge, and the reaction process does not require the addition of chemical reagents such as H2O2. These results indicated that SSBC/ZVI micro electrolysis was suitable for CSPW pretreatment.
Table 4
Comparative analysis of pretreatment methods for biodegradability improvement of real chemical synthesis-based pharmaceutical wastewater
Wastewater type
|
Physicochemical characteristics
|
Pretreatment methods
|
Biodegradability enhancement
|
References
|
Cephalosporins, and anticancer drugs synthesis wastewater
|
916 mg/L COD
|
SSBC/ZVI micro-electrolysis
|
BI value enhanced from 0.17 to 0.39
|
This study
|
Paracetamol manufacturing wastewater
|
1390 mg/L COD
|
O3/nZVI
|
BI value enhanced from 0.18 to 0.63
|
[3]
|
Not stated
|
60000–80000 mg/L COD
|
CoMnAl-CMO-Al2O3/H2O2 oxides catalyst
|
BI value increased from 0.173 to 0.464
|
[35]
|
Active pharmaceutical ingredients manufacturing wastewater
|
7010 mg/L COD
|
Fenton
|
Biodegradability (TOC removal by biological processes) increased from 17–97%
|
[7]
|
Etodolac manufacturing wastewater
|
Up to 7500 mg/L of COD
|
Ozonation process
|
COD removal efficiency increased from 50% to 85–90%
|
[38]
|
Steroid hormone synthesis wastewater
|
13189–16644 mg/L COD
|
Combined interior micro-electrolysis and Fenton oxidation coagulation
|
BI value increased from 0.21 to 0.59
|
[5]
|
Cephalosporin synthesis wastewater
|
2169 mg/L of COD
|
Microwave-assisted Fenton-like (MW-Fenton-like) process
|
BI value increased from 0.23 to 0.40
|
[36]
|
Mixed chemical wastewater
|
400–800 mg/L of COD
|
Internal electrolysis
|
BI value increased from 0.3 to 0.6
|
[11]
|
Cardiovascular and venous diseases drugs synthesis wastewater
|
1901 mg/L of COD
|
Heterogeneous catalytic wet peroxide oxidation (CWPO) process using an Fe2O3/SBA-15 nano composite catalyst
|
BI value increased from 0.2 to 0.3
|
[37]
|