1. Fallon JB, Irvine DRF, Shepherd RK. Cochlear implants and brain plasticity. Hear Res. 2008;238(1-2):110-7. doi:10.1016/j.heares.2007.08.004.
2. US Department of Health & Human Services NIoDaoCD. Cochlear Implants. 2017.
3. Todt I, Tittel A, Ernst A, Mittmann P, Mutze S. Pain Free 3 T MRI Scans in Cochlear Implantees. Otology & Neurotology. 2017;38(10):e401-e4. doi:10.1097/mao.0000000000001569.
4. Stark T, Helbig S. [Cochlear implantation: a changing indication]. Hno. 2011;59(6):605-14. doi:10.1007/s00106-011-2309-9.
5. Xiang X, Cao F. Time window and "tissue window": two approaches to assist decision-making in strokes. J Neurol. 2019;266(2):283-8. doi:10.1007/s00415-018-8933-5.
6. Chen X, Liu Y, Tong H, Dong Y, Ma D, Xu L et al. Meta-analysis of computed tomography angiography versus magnetic resonance angiography for intracranial aneurysm. Medicine (Baltimore). 2018;97(20):e10771. doi:10.1097/md.0000000000010771.
7. Lingam RK, Connor SEJ, Casselman JW, Beale T. MRI in otology: applications in cholesteatoma and Meniere's disease. Clin Radiol. 2018;73(1):35-44. doi:10.1016/j.crad.2017.09.002.
8. Forgues M, Mehta R, Anderson D, Morel C, Miller L, Sevy A et al. Non-contrast magnetic resonance imaging for monitoring patients with acoustic neuroma. J Laryngol Otol. 2018;132(9):780-5. doi:10.1017/s0022215118001342.
9. Hartwig V, Giovannetti G, Vanello N, Lombardi M, Landini L, Simi S. Biological effects and safety in magnetic resonance imaging: a review. Int J Environ Res Public Health. 2009;6(6):1778-98. doi:10.3390/ijerph6061778.
10. Nospes S, Brockmann MA, Lassig A. [MRI in patients with auditory implants equipped with implanted magnets-an update : Overview and procedural management]. Radiologe. 2019;59(1):48-56. doi:10.1007/s00117-018-0462-9.
11. Kim BG, Kim JW, Park JJ, Kim SH, Kim HN, Choi JY. Adverse events and discomfort during magnetic resonance imaging in cochlear implant recipients. JAMA Otolaryngol Head Neck Surg. 2015;141(1):45-52. doi:10.1001/jamaoto.2014.2926.
12. Majdani O, Leinung M, Rau T, Akbarian A, Zimmerling M, Lenarz M et al. Demagnetization of cochlear implants and temperature changes in 3.0T MRI environment. Otolaryngol Head Neck Surg. 2008;139(6):833-9. doi:10.1016/j.otohns.2008.07.026.
13. Hassepass F, Stabenau V, Maier W, Arndt S, Laszig R, Beck R et al. Revision surgery due to magnet dislocation in cochlear implant patients: an emerging complication. Otol Neurotol. 2014;35(1):29-34. doi:10.1097/MAO.0b013e3182a5d2c5.
14. Limited C. MRI Guidelines. https://www.cochlear.com/us/en/professionals/resources/mri-guidelines. 2019. Accessed 27.03.2020.
15. MEDEL. MED-EL Announces FDA Approval of PULSAR, SONATA and MED-EL CONCERT Cochlear Implants for 1.5T MRI. https://s3.medel.com/pdf/US/Final_MRI_FDA_Approval_Press_Release_06_14_13.pdf2013.
16. Carlson ML, Neff BA, Link MJ, Lane JI, Watson RE, McGee KP et al. Magnetic Resonance Imaging With Cochlear Implant Magnet in Place: Safety and Imaging Quality. Otol Neurotol. 2015;36(6):965-71. doi:10.1097/mao.0000000000000666.
17. Crane BT, Gottschalk B, Kraut M, Aygun N, Niparko JK. Magnetic resonance imaging at 1.5 T after cochlear implantation. Otol Neurotol. 2010;31(8):1215-20. doi:10.1097/MAO.0b013e3181ec1d61.
18. Majdani O, Rau TS, Gotz F, Zimmerling M, Lenarz M, Lenarz T et al. Artifacts caused by cochlear implants with non-removable magnets in 3T MRI: phantom and cadaveric studies. Eur Arch Otorhinolaryngol. 2009;266(12):1885-90. doi:10.1007/s00405-009-0994-8.
19. Sharon JD, Northcutt BG, Aygun N, Francis HW. Magnetic Resonance Imaging at 1.5 Tesla With a Cochlear Implant Magnet in Place: Image Quality and Usability. Otol Neurotol. 2016;37(9):1284-90. doi:10.1097/mao.0000000000001176.
20. Edmonson HA, Carlson ML, Patton AC, Watson RE. MR Imaging and Cochlear Implants with Retained Internal Magnets: Reducing Artifacts near Highly Inhomogeneous Magnetic Fields. Radiographics. 2018;38(1):94-106. doi:10.1148/rg.2018170135.
21. Mugler JP, 3rd, Brookeman JR. Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE). Magn Reson Med. 1990;15(1):152-7. doi:10.1002/mrm.1910150117.
22. Glueckert R, Johnson Chacko L, Schmidbauer D, Potrusil T, Pechriggl EJ, Hoermann R et al. Visualization of the Membranous Labyrinth and Nerve Fiber Pathways in Human and Animal Inner Ears Using MicroCT Imaging. Front Neurosci. 2018;12:501-. doi:10.3389/fnins.2018.00501.
23. Todt I, Rademacher G, Mittmann P, Wagner J, Mutze S, Ernst A. MRI Artifacts and Cochlear Implant Positioning at 3 T In Vivo. Otol Neurotol. 2015;36(6):972-6. doi:10.1097/mao.0000000000000720.
24. Schroder D, Grupe G, Rademacher G, Mutze S, Ernst A, Seidl R et al. Magnetic Resonance Imaging Artifacts and Cochlear Implant Positioning at 1.5 T In Vivo. Biomed Res Int. 2018;2018:9163285. doi:10.1155/2018/9163285.
25. Wagner F, Wimmer W, Leidolt L, Vischer M, Weder S, Wiest R et al. Significant Artifact Reduction at 1.5T and 3T MRI by the Use of a Cochlear Implant with Removable Magnet: An Experimental Human Cadaver Study. PLoS One. 2015;10(7):e0132483. doi:10.1371/journal.pone.0132483.