A Modified Single-Endobutton Technique Combined with Nice Knot for Treatment of Rockwood Type III Acromioclavicular Joint Dislocation

DOI: https://doi.org/10.21203/rs.3.rs-726778/v1

Abstract

Purpose: Double-endobutton technique, as a widely accepted strategy for the treatment of acromioclavicular joint dislocation , is undergoing constant improvement. This study was to assess the clinical effect of a modified single-endobutton combined with nice knot in the fixation of Rockwood type III acromioclavicular joint dislocation.

Methods: From January 2016 to January 2018, 16 adult patients (13 males and 3 females) with Rockwood type III acromioclavicular joint dislocation were treated with a modified single-endobutton technique combined with nice knot in our department. The age ranged from 18 to 64 years old with an average of 32.8 years old. Operative time and intraoperative blood loss were recorded, post-operative clinical outcomes and radiographic results were recorded and analyzed. Preoperative and last follow up scores in the Constant-Murley Scale, Neer score, Rating Scale of the American Shoulder and Elbow Surgeons and VAS scale and complications such as infection, re-dislocation, implant loosening, medical origin fracture and hardware pain were recorded and evaluated.

Results: 16 patients were followed up for 6 to 18 months with an average of 10.3 months. The operative time was 50-90 minutes with an average of (62.5±3.10) min. The intraoperative blood loss was 30-100 ml, with an average of (55.0±4.28) ml. The complications, such as wound infection, internal fixation failure and fractures, were not found in these cases. According to Karlsson criteria, there were excellent in 14 cases, good in 2 cases at the final follow up. The mean VAS score of the patients was 5.88±0.26 preoperatively, compared with 0.19±0.14 at the final follow-up evaluation. The difference was statistically significant (P<0.01). The mean Constant score was 45.5±2.0 preoperatively, compared to 94.0±0.73 at the final follow-up evaluation. The difference was statistically significant (P<0.01).

Conclusion: Nice knot provides a reliable fixation for the single-Endobutton technique in the treatment of acromioclavicular dislocations. The modified single-Endobutton technique combined with nice knot can achieve good clinical outcomes in treatment of Rockwood type III acromioclavicular joint dislocation.

Introduction

The acromioclavicular joint is a complex linkage joint consisting of the acromioclavicular joint surface and the acromioclavicular ligament, rostral ligament and joint capsule, which anchors the clavicle to the scapula. The movement of the scapula is extremely complex and therefore treatment of a scaphoid injury can be very difficult[1]. Acromioclavicular joint dislocation is a common type of acromioclavicular joint injury, accounting for approximately 9% of shoulder injuries. Acromioclavicular joint dislocation is a common type of acromioclavicular joint injury, accounting for approximately 9% of shoulder injuries. It is most commonly seen in shoulder sports injuries and is mainly caused by impingement on the shoulder crest when the upper arm is in an inversion position[2]. The Rockwood staging system is often used for acromioclavicular dislocations and is divided into types I-VI[3]. For Rockwood type I-II injuries with a small dislocation of the acromioclavicular joint, conservative treatment is possible. Rockwood IV-VI is recommended for surgery due to the severity of the injury and the large displacement of the acromioclavicular joint. The treatment of Rockwood type III injuries is still controversial[4, 5]. Some research[6] indicates that surgical treatment does not improve the general health status of patients compared to non-surgical treatment. Studies[7] have shown that Rockwood III can be treated surgically to restore the normal anatomy of the acromioclavicular joint, re-establish joint stability and achieve good functional outcomes. Therefore, for young patients with high activity levels, surgery is recommended[3]. The most commonly used surgical procedure is internal fixation with double Endobutton technique[811]. However, the procedure can be complicated by collar plates trapped in the bone channel, fractures of the rostral process or clavicle, and loosening of the knot after the operation[12].

Pascal Boileau[13] described a new, simple and effective self-locking sliding two-wire knot (Fig. 1). And instead of wire cables, nice knot is used to fix tendons, ligaments, fractures, etc. Studies[14, 15] also showed that nice knot has good biomechanical properties. In fact, the nice knot has been reported to be superior for comminuted patellar fractures, clavicle fractures and for closure of small and medium sized trauma[1620]. Recently, the nice knot has been used in combination with the double endobutton to treat acromioclavicular dislocations with good clinical results[21].

Therefore, we have modified the double endobutton technique by replacing the double collar with a single collar plate and wrapping it around the rostral process, combined with nice knot internal fixation for acute acromioclavicular dislocation. This study investigates the clinical efficacy of the nice knot-assisted modified single-Endobutton technique in the treatment of acute Rockwood III acromioclavicular dislocation.

Materials And Methods

The study was approved by our ethics committee and all patients gave their informed consent and signed the informed consent form.

Patient selection

Patient inclusion criteria(1) Closed unilateral Rockwood III subluxation of the acromioclavicular joint;(2) Age ≧ 18 years;(3) Normal shoulder function before the injury;(4) Patient follows our treatment plan. Patient exclusion criteria:(1) Patients with a combined distal clavicle or scaphoid fracture;(2) Patients with open injuries or vascular or nerve damage;(3) Age <18 years;(4) Patients with severe osteoporosis;(5) Patients with co-morbidities that cannot tolerate surgery;(6) Patients who refuse surgical treatment.

Review of 16 consecutive patients who had unilateral Rockwood III acromioclavicular dislocations treated with modified single-Endobutton technique combined with nice knot at our hospital from January 2016 to June 2019. All patients had a closed injury and were admitted to the hospital with a positive X-ray of both shoulders and a lateral X-ray, CT and MRI of the affected shoulder to clarify the diagnosis and improve the preoperative examination. All were treated with a modified single-Endobutton collar plate technique combined with nice knot surgery, with intraoperative and postoperative X-ray fluoroscopy. Regular post-operative follow-up was performed.

Operative technique

All operations are performed by the same surgeon team. The patient is under general anaesthesia and in the beach chair position A longitudinal incision of approximately 3cm is then made vertically upwards around the coracoid to reveal the coracoid process conjunctive tendon and coracoid root. The injured limb is internally rotated in the inward position, and a traction wire is placed along the base of the coracoid from inward to outward around the coracoid and into a reserve. Bone channels of 2mm each drilled 1.5cm and 3cm distal to the acromioclavicular joint and 2cm anterior to the posterior border of the clavicle. The traction wire is placed in the bone channel and reserved for use. The double-Endobutton is split and keep only the single-Endobutton. The two strands of Endobutton suture are folded into four strands and introduced through the medial hole of the clavicle, around the rostral process and leading out at the lateral hole of the clavicle, respectively out of the hole of Endobutton. The acromioclavicular joint is repositioned and fixed on the Endobutton using the nice knot and gradually tightened. Intraoperatively, the acromioclavicular joint was observed with C-arm fluoroscopy. If the joint was repositioned, at least three single knots were added to the nice knot to strengthen the fixation (Fig. 2).

Pre- and post-operative management

Pre-operative imaging is performed to measure and mark the distance from the clavicle to the coracoid on both sides of the patient and the distance from the base of the coracoid to the acromioclavicular joint on X-ray. The patient is well under anesthesia and initially positioned to mark the incision location. Post-operative fluoroscopy showed that the acromioclavicular joint was well repositioned (Fig. 3). The surgical time(min) was recorded as the time from skin incision to closure of the wound. Intraoperative blood loss(ml), fluoroscopy time(s) and postoperative complications as well were recorded. All patients had X-rays taken the day after surgery and were given functional exercises in a forearm sling suspension. Active forward flexion, extension and abduction of the shoulder joint started 1 week after surgery. Partial weight-bearing on the shoulder joint started 2 months after surgery. Full weight bearing was allowed 3-6 months after surgery. Patients were followed up regularly at 3 weeks, 6 weeks, 3 months, 6 months and 12 months after surgery to guide rehabilitation and functional exercises (Fig. 4). At preoperative and final follow-up, patients' shoulder function was evaluated according to the Visual Analgesia Score (VAS), Neer score, American Shoulder and Elbow Surgeon Scale (ASE), and Constant-Murley score.

Statistical analysis

All data were analyzed using IBM SPSS Statistics 23.0 statistical software for analysis. Parametric data, such as operative time, fluoroscopy time and blood loss, described as mean ± standard deviation. Pearson's chi-square test and Fisher's exact test for comparing classification results. A paired t-test was used to compare post-operative and pre-operative functional scores. Statistical significance level was set at P-value ≤ 0.05.

Results

Of the 16 patients included with Rockwood III acromioclavicular dislocation, 12 were male patients and 4 were female patients. The patients' ages ranged from 18 to 65 years with a mean of (36.7±12.7); five of them had a history of smoking and alcohol; statistics showed that six were left-sided and ten were right-sided. The mechanism of injury was traffic injury in 9 cases, direct violence in 1 case and a fall in 6 cases. The patient's BMI was 12.9±4.8 (range 6.9-24.8); the anesthesia record sheet showed operation time was 62.5±12.4 min, (range 50-90 min); intraoperative bleeding was 55.0±17.1 ml (range 30-100) ml. The patient's time in hospital was 5.8±0.8 days (5-7d). (Tables 1 and 2).

 Table 1 Patient demographics

Variable


No. of cases

16

Gender (M/F)

12/4

Age (Year, mean±SD)

36.7±12.7

BMI(, mean±SD)

12.9±4.8

History of tobacco and alcohol (Y/N)

5/11

Left or Right (L/R)

6/10

Injury mechanism


Traffic accidents

9/16

Direct violent injury

1/16

Fall

6/16

Follow-up time(month, mean±SD)

13.1±2.3

 Table 2 Operation related factors

Variable

 

Operative time (min, mean±SD)

62.5±12.4

Blood loss (ml, mean±SD)

55.0±17.1

Fluoroscopy time (s, mean±SD)

8.6±1.7

Hospitalization days(d, mean±SD)

5.8±0.8

 Table 3 Postoperative follow-up results

Group

Pre-op

Pre-op

P

ASES (mean±SD)

46.2±4.9

94.8±1.9

<0.05

Neer score (mean±SD)

46.3±5.3

94.1±2.1

<0.05

Constant-Murley score (mean±SD)

45.5±8.0

93.8±2.3

<0.05

VAS(mean±SD)

5.9±1.0

0.3±0.6

<0.05

All patients received 13.1 ± 2.3 (range 6-18) months of follow-up. There were no complications such as infection or vascular or neurological damage, no cases of rostral or clavicle fractures, and no loosening or breaking of internal fixations.

The shoulder joint was well repositioned at the final follow-up, with 14 excellent cases and 2 good cases, representing an excellent rate of 100%. The preoperative VAS score was 5.9±1.0 (range 4-8) and the VAS score at the last follow-up was 0.3±0.6 (range 0-2), with a statistically significant difference (p<0.01). The preoperative Constant-Murley score was 45.5±8.0 (range 30-56) and the Constant-Murley score at the last follow-up was 93.8±2.3 (range 87-98), a statistically significant difference (P<0.01). The American Shoulder and Elbow Surgeon Score (ASES) at the last follow-up was 94.8±1.9 (range 92-99), which was significantly higher than the preoperative ASES of 46.2±4.9 (range 39-53) (p<0.01). The final follow-up Neer score was 94.1±2.1 (range 90-98), a significant increase from the preoperative Neer score of 46.3±5.3 (range 38-54) (P<0.01). (Tables 3).

Discussion

The Nice knot has advantages such as sliding locking, easy operation and reliable fixing power. Boileau[13] reports on the versatility of the nice knot for arthroscopic repair of tendon and ligament injuries, for binding post-osteotomy fractures and for repositioning and fixing butterfly fractures in fractures, as well as for repairing the separation of the inferior tibiofibular joint in fixation. Mengcun Chen[20] applied nice knot to comminuted patella fracture and achieved good clinical results. P Collin[14] analyzed the biomechanics of the nice knot in the repair of rotator cuff injuries and concluded that the knot provided good sliding lock and significantly reduced the risk of knot elongation during dynamic strain. On the application of nice knot in acromioclavicular dislocation, Zhongxing Ma[21] proposed a modified double endobutton technique in combination with Nice knot for the treatment of Rockwood III-V acromioclavicular dislocation, and achieved good clinical results. We have modified the Endobutton technique by replacing the double-endobutton with a single-endobutton and using the nice knot to treat Rockwood III-V acromioclavicular dislocations, making it easier and more convenient to reposition the acromioclavicular dislocation intraoperatively.

There are various surgical options for dislocation of the acromioclavicular joint, such as fixation with pins, screws or plates, as well as reconstruction of the rostral or acromioclavicular ligaments or distal clavicle resection. More complications associated with internal fixation of the acromioclavicular joint dislocation with Clinique pins[22, 23]. The most commonly used surgical procedures are the clavicle hook plate fixation[24], the Endobutton technique[21, 25, 26] and the Tightrope[27, 28] coracoid collateral ligament repair and reconstruction.

Clavicle hook plate internal fixation is the current treatment for acromioclavicular joint dislocation[24]. Clavicle hook plate provides mechanical stability in the longitudinal and horizontal directions. However, there is a high incidence of complications, including postoperative shoulder pain, limited shoulder movement, foreign body sensation, rotator cuff injury, acromion impingement syndrome, osteolysis of the acromion, distal clavicle fracture and plate fracture[2934]. In addition, the patient will need to remove the internal fixation device a second time.

The double-Endobutton technique for the treatment of acromioclavicular dislocations was first reported by Struhl[26] in 2007 and has since been widely used. Endobutton system consisting of titanium plates, coils and sutures. During the operation, the acromioclavicular joint was repositioned and temporarily fixed with a Kirschner pin. The base of coracoid process and clavicle were drilled successively. The two titanium plates of the Endobutton are fixed by coils above the clavicle and below the coracoid. The reconstruction of the conical and trapezius ligaments was achieved by drilling holes in various parts of the distal clavicle. The double Endobutton technique significantly improves the patient's early shoulder pain, range of motion in shoulder abduction supination and forward flexion supination. However, biomechanical studies[35] have shown that the Endobutton technique fails mainly because the strength of the coils is greater than the strength of the bone under overload conditions, resulting in bone damage. The main complications of this technique are fractures of the clavicle or rostral process, loss of repositioning, calcification of the rostral-clavicular ligament and traumatic acromioclavicular arthritis[3537]. In addition, the Endobutton technique only limits the up and down displacement of the clavicle and lacks horizontal stability[38].

The Tightrope technique is a new system that has emerged in recent years to reconstruct the rostro-clavicular ligament and can be considered an improved upgrade to the Endobutton system. It combines the advantages of the Endobutton system and can be adjusted to the length of the coil as required. Studies[35, 39] have shown that the Tightrope technique offers significant advantages in terms of stability and postoperative clinical outcomes. However, it is still at risk of acromion fracture[40].

According to the characteristics of Endobutton technology, we improve the technology in the following aspects: (1) Intraoperative 4.5 mm bone tracts are no longer used. We believe that the 4.5 mm bone channel is too large for the plate to sink into the bone channel. Intraoperative positioning at the central base of the coracoid is particularly difficult, especially in the absence of arthroscopic surveillance, and if the position is shifted intraoperatively, the fracture at the base of the coracoid is easily fractured and fixation fails[12, 41]. Two 2mm channels are drilled in the distal clavicle at 1.5cm and 3cm medially, the coil is passed through the channel and around the base of the coracoid, and the plate is placed on the clavicle and fixed with a nice knot. This not only reduces the risk of fracture from drilling the rostral process, but also reduces the diameter of the process and prevents the plate from sinking into the bone. The surgical incision is minor and does not have to rely on arthroscopic assistance. (2) We drill two bone channels in the clavicle, which is equivalent to reconstructing the vertebral and oblique ligaments at the same time, without additional operations. (3) After the dislocation of acromioclavicular joint was reduced intraoperatively, the clavicle was fixed with Nice Knot. The main feature of the nice Knot is that it can be slid and locked. The knot can be tightened during surgery and then the acromioclavicular joint can be reduced by fluoroscopy. In this group, we treated 16 patients with Rockwood III acromioclavicular dislocation using the nice knot combined with the modified Endobutton technique. No complications such as coracoid fracture, re-dislocation of the acromioclavicular joint or vascular nerve injury were observed after surgery. Post-operative follow-up showed a significant improvement in the function of the affected shoulder compared to the pre-operative period. In the treatment of Rockwood III-V acromioclavicular dislocation with the nice knot assisted modified Endobutton technique, we believe that attention should be made to the following:(1) This technique is not recommended for elderly patients with osteoporosis as there is a risk of fracture of the coronoid due to wire loop cutting. (2) The technique involves wrapping the thread around the base of the coracoid. The limb should be placed in the medial position and the anterior ring introduced against the base of the coracoid and the underlying bone to avoid damage to the brachial plexus nerve and the axillary sheath below the coracoid process. (3) The soft tissues around the acromioclavicular joint and clavicular area scar within 4–6 weeks after surgery. Therefore, a forearm sling should be used for 4 weeks postoperatively to avoid excessive abduction leading to loss of reduction.

Although our data showed good clinical results in terms of operative time, intraoperative fluoroscopy time, intraoperative bleeding, and satisfaction with repositioning, there are still some shortcomings in this study:(1) This study is a single-center retrospective clinical case analysis with a low level of evidence and a small number of cases, and a multi-center, large sample case analysis is required to confirm the results of this study. The practicality and feasibility of the nice knot combined with the modified single-endobutton technique for Rockwood III acromioclavicular dislocations needs to be studied in a large sample. (2) The variables in this study are not unique and there is some selection bias. (3) Although the clinical and imaging results of nice knot are good, more long-term follow-up results are needed to determine whether there are long-term complications.

Conclusion

In conclusion, the nice knot combined with the modified single-endobutton technique for Rockwood III acromioclavicular dislocations is an option for the treatment of acromioclavicular dislocations as it makes intraoperative reduction easier, has significant clinical efficacy, improves the function of the shoulder joint, reduces pain and reduces complications. We will further expand the sample size and extend the follow-up period in future work in order to better improve the technique.

Declarations

Ethics approval and consent to participate: The experimental protocol was established, according to the ethical guidelines of the Helsinki Declaration and was approved by the Human Ethics Committee of Shandong Provincial Hospital Affiliated to Shandong First Medical University. Written informed consent was obtained from each study participants.

Consent for publication: Not applicable.

Availability of data and materials: All data generated or analyzed during this study are included in this published article.

Competing interests: The authors declare that they have no competing interests.

Funding: Not applicable.

Authors' contributions: Bomin Wang and Yongliang Yang conceived of the presented idea. Fangning Hu wrote the main manuscript text. Fangning Hu and Shumei Han prepared figures and tables. All authors reviewed the manuscript.

Acknowledgements: We appreciated all the follow-up patients for the help and support.

References

  1. Mazzocca AD, Arciero RA,Bicos J. Evaluation and treatment of acromioclavicular joint injuries. Am J Sports Med, 2007, 35: 316-29.
  2. Chillemi C, Franceschini V, Dei Giudici L, Alibardi A, Salate Santone F, Ramos Alday LJ, et al. Epidemiology of isolated acromioclavicular joint dislocation. Emergency medicine international, 2013, 2013: 171609.
  3. Korsten K, Gunning AC,Leenen LP. Operative or conservative treatment in patients with Rockwood type III acromioclavicular dislocation: a systematic review and update of current literature. Int Orthop, 2014, 38: 831-8.
  4. Tang G, Zhang Y, Liu Y, Qin X, Hu J,Li X. Comparison of surgical and conservative treatment of Rockwood type-III acromioclavicular dislocation: A meta-analysis. Medicine (Baltimore), 2018, 97: e9690.
  5. Longo UG, Ciuffreda M, Rizzello G, Mannering N, Maffulli N,Denaro V. Surgical versus conservative management of Type III acromioclavicular dislocation: a systematic review. British medical bulletin, 2017, 122: 31-49.
  6. Mah JM. General Health Status After Nonoperative Versus Operative Treatment for Acute, Complete Acromioclavicular Joint Dislocation: Results of a Multicenter Randomized Clinical Trial. J Orthop Trauma, 2017, 31: 485-90.
  7. Steinbacher G, Sallent A, Seijas R, Boffa JM, Espinosa W,Cugat R. Clavicular hook plate for grade-III acromioclavicular dislocation. J Orthop Surg (Hong Kong), 2014, 22: 329-32.
  8. Zhu RT, Ying YR, Gao FM, Wang B, Chen M, Ying GH, et al. [Clinical study on the treatment of acromioclavicular joint dislocation of tossy grade III with double endobutton]. Zhongguo Gu Shang, 2009, 22: 653-4.
  9. Beris A, Lykissas M, Kostas-Agnantis I, Vekris M, Mitsionis G,Korompilias A. Management of acute acromioclavicular joint dislocation with a double-button fixation system. Injury, 2013, 44: 288-92.
  10. Torkaman A, Bagherifard A, Mokhatri T, Haghighi MH, Monshizadeh S, Taraz H, et al. Double-button Fixation System for Management of Acute Acromioclavicular Joint Dislocation. Arch Bone Jt Surg, 2016, 4: 41-6.
  11. Teodoro RL, Nishimi AY, Pascarelli L, Bongiovanni RR, Velasco MAP,Dobashi ET. Surgical treatment of acromioclavicular dislocation using the endobutton. Acta Ortop Bras, 2017, 25: 81-84.
  12. Woodmass JM, Esposito JG, Ono Y, Nelson AA, Boorman RS, Thornton GM, et al. Complications following arthroscopic fixation of acromioclavicular separations: a systematic review of the literature. Open access journal of sports medicine, 2015, 6: 97-107.
  13. Boileau P, Alami G, Rumian A, Schwartz DG, Trojani C,Seidl AJ. The Doubled-Suture Nice Knot. Orthopedics, 2017, 40: e382-e86.
  14. Collin P, Laubster E, Denard PJ, Akuè FA,Lädermann A. The Nice knot as an improvement on current knot options: A mechanical analysis. Orthopaedics & traumatology, surgery & research : OTSR, 2016, 102: 293-6.
  15. Hill SW, Chapman CR, Adeeb S, Duke K, Beaupre L,Bouliane MJ. Biomechanical evaluation of the Nice knot. International journal of shoulder surgery, 2016, 10: 15-20.
  16. Kang Y, Ma Y, Rui Y, Li F, Liu J, Gu J, et al. [Effectiveness of Nice knot combined with elastic intramedullary nailing fixation in treatment of Robinson type 2B midshaft clavicular fracture in adults]. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi, 2019, 33: 1394-98.
  17. Wu G, Chen YQ, Chen CY, Lin ZX, Xie QY, Ye JJ, et al. Clinical outcomes of doubled-suture Nice knot augmented plate fixation in the treatment of comminuted midshaft clavicle fracture. BMC surgery, 2021, 21: 270.
  18. Hu F, Liu X, Liu F, Jia H, Lv X, Wang F, et al. Intraoperative Nice knots assistance for reduction in displaced comminuted clavicle fractures. BMC Musculoskelet Disord, 2021, 22: 467.
  19. Xu J, Chang R, Zhang W, Zhang C, Zhu D, Liu F, et al. Skin stretch suturing with Nice knots in the treatment of small- or medium-sized wounds. J Orthop Surg Res, 2020, 15: 488.
  20. Chen M, Jin X, Fryhofer GW, Zhou W, Yang S, Liu G, et al. The application of the Nice knots as an auxiliary reduction technique in displaced comminuted patellar fractures. Injury, 2020, 51: 466-72.
  21. Ma ZX, Du YH,Wu D. [Modified Double-Endobutton technique combined with Nice knot in the treatment of Rockwood Ⅲ-Ⅴ acromioclavicular joint dislocation]. Zhongguo Gu Shang, 2020, 33: 703-6.
  22. Batın S, Ozan F, Gürbüz K, Uzun E, Kayalı C,Altay T. Migration of a Broken Kirschner Wire after Surgical Treatment of Acromioclavicular Joint Dislocation. Case reports in surgery, 2016, 2016: 6804670.
  23. Mankowski B, Polchlopek T, Strojny M, Grala P,Slowinski K. Intraspinal migration of a Kirschner wire as a late complication of acromioclavicular joint repair: a case report. J Med Case Rep, 2016, 10: 66.
  24. Balke M, Schneider MM, Akoto R, Bäthis H, Bouillon B,Banerjee M. [Acute acromioclavicular joint injuries. Changes in diagnosis and therapy over the last 10 years]. Unfallchirurg, 2015, 118: 851-7.
  25. Zhang L, Zhou X, Qi J, Zeng Y, Zhang S, Liu G, et al. Modified closed-loop double-endobutton technique for repair of rockwood type III acromioclavicular dislocation. Exp Ther Med, 2018, 15: 940-48.
  26. Struhl S. Double Endobutton Technique for Repair of Complete Acromioclavicular Joint Dislocations. Techniques in Shoulder and Elbow Surgery. 2007, 8: 175-9.
  27. Hashiguchi H, Iwashita S, Abe K, Sonoki K, Yoneda M,Takai S. Arthroscopic Coracoclavicular Ligament Reconstruction for Acromioclavicular Joint Dislocation. Journal of Nippon Medical School = Nippon Ika Daigaku zasshi, 2018, 85: 166-71.
  28. Özcafer R, Albayrak K, Lapçin O, Çetinkaya E, Arıkan Y,Gül M. Early clinical and radiographic results of fixation with the TightRope device for Rockwood type V acromioclavicular joint dislocation: A retrospective review of 15 patients. Acta Orthop Traumatol Turc, 2020, 54: 473-77.
  29. Sun S, Gan M, Sun H, Wu G, Yang H,Zhou F. Does Subacromial Osteolysis Affect Shoulder Function after Clavicle Hook Plating? BioMed research international, 2016, 2016: 4085305.
  30. Lin HY, Wong PK, Ho WP, Chuang TY, Liao YS,Wong CC. Clavicular hook plate may induce subacromial shoulder impingement and rotator cuff lesion--dynamic sonographic evaluation. J Orthop Surg Res, 2014, 9: 6.
  31. Yagnik GP, Jordan CJ, Narvel RR, Hassan RJ,Porter DA. Distal Clavicle Fracture Repair: Clinical Outcomes of a Surgical Technique Utilizing a Combination of Cortical Button Fixation and Coracoclavicular Ligament Reconstruction. Orthop J Sports Med, 2019, 7: 2325967119867920.
  32. Gstettner C, Tauber M, Hitzl W,Resch H. Rockwood type III acromioclavicular dislocation: surgical versus conservative treatment. Journal of shoulder and elbow surgery, 2008, 17: 220-5.
  33. ElMaraghy AW, Devereaux MW, Ravichandiran K,Agur AM. Subacromial morphometric assessment of the clavicle hook plate. Injury, 2010, 41: 613-9.
  34. Natera Cisneros LG,Sarasquete Reiriz J. Acute high-grade acromioclavicular joint injuries: quality of life comparison between patients managed operatively with a hook plate versus patients managed non-operatively. Eur J Orthop Surg Traumatol, 2017, 27: 341-50.
  35. Li Q, Hsueh PL,Chen YF. Coracoclavicular ligament reconstruction: a systematic review and a biomechanical study of a triple endobutton technique. Medicine (Baltimore), 2014, 93: e193.
  36. Thangaraju S, Cepni S, Magosch P, Tauber M, Habermeyer P,Martetschläger F. Arthroscopically assisted acromioclavicular joint stabilization leads to significant clavicular tunnel widening in the early post-operative period. Knee Surg Sports Traumatol Arthrosc, 2019, 27: 3821-26.
  37. Lu D, Wang T, Chen H,Sun LJ. A comparison of double Endobutton and triple Endobutton techniques for acute acromioclavicular joint dislocation. Orthopaedics & traumatology, surgery & research : OTSR, 2016, 102: 891-95.
  38. Wellmann M, da Silva G, Lichtenberg S, Magosch P,Habermeyer P. [Instability pattern of acromioclavicular joint dislocations type Rockwood III: relevance of horizontal instability]. Der Orthopade, 2013, 42: 271-7.
  39. Pan X, Lv RY, Lv MG,Zhang DG. TightRope vs Clavicular Hook Plate for Rockwood III-V Acromioclavicular Dislocations: A Meta-Analysis. Orthopaedic surgery, 2020, 12: 1045-52.
  40. Walz L, Salzmann GM, Fabbro T, Eichhorn S,Imhoff AB. The anatomic reconstruction of acromioclavicular joint dislocations using 2 TightRope devices: a biomechanical study. Am J Sports Med, 2008, 36: 2398-406.
  41. Chen K, Xu B, Lao YJ,Yang Y. Risk factors related to the loss of reduction after acromioclavicular joint dislocation treated with the EndoButton device. Annals of translational medicine, 2021, 9: 345.