Effect of Early Supraglottic Airway Device Insertion on Chest Compression Fraction during Simulated Out-of-Hospital Cardiac Arrest: Randomized Controlled Trial

DOI: https://doi.org/10.21203/rs.3.rs-778473/v1

Abstract

Early insertion of a supraglottic airway (SGA) device could improve CCF by allowing providers to perform continuous chest compressions or by shortening the interruptions needed to deliver ventilations. SGA devices do not require the same expertise as endotracheal intubation. This study aimed to determine whether the immediate insertion of an i-gel® while providing continuous chest compressions with asynchronous ventilations could generate higher CCFs than the standard 30:2 approach using a face-mask in a simulation of OHCA. A multicenter, parallel, randomised, superiority, simulation study was carried out. The primary outcome was the difference in CCF during the first two minutes of resuscitation. Overall and per-cycle CCF, quality of compressions and ventilations parameters were also compared. Among 13 teams of two participants, the early insertion of an i-gel® resulted in higher CCFs during the first two minutes (89.0% vs 83.6%, p=0.001). Overall and per-cycle CCF were consistently higher in the i-gel® group, even after the 30:2 alternation had been resumed. In this group, ventilation parameters were enhanced, but compressions were significantly shallower (4.6 cm vs 5.2 cm, p=0.007). This latter issue must be addressed before clinical trials can be considered.

Trial registration: NCT04736446 (03/02/2021)

Introduction

Background

High-quality chest compressions are mandatory to increase the probability of survival after out-of-hospital cardiac arrest (OHCA)1,2. One of the key determinants of survival and favourable neurological outcome is the chest compression fraction (CCF) i.e., the proportion of time spent performing compressions during cardiopulmonary resuscitation (CPR)3–10. An increase of 10% in CCF can even yield a 11% increase in survival.6 

The optimal airway management strategy for OHCA is still debated11–17, and airway management maneuvers might lead to interruptions in chest compressions, thereby preventing rescuers from achieving high CCFs. Even though endotracheal intubation (ETI) is often considered as the gold standard, this technique requires great skill that must be maintained by regular practice to be both safe and efficient18–20. However, most prehospital providers are either insufficiently trained in ETI or lack the possibility of maintaining this skill. Supraglottic airway (SGA) devices might therefore represent an adequate solution in many settings as their use does not require the same level of expertise. There are many different SGA devices, some of which are easier to use than others. Conversely to traditional laryngeal mask airways, the i-gel® embeds a thermoplastic cuff which does not need to be inflated, making its insertion quicker and allowing high success rates to be achieved21–31. In addition, SGA devices seem to confer a certain degree of airway protection as the rates of regurgitation and aspiration do not significantly differ from those seen with ETI in case of OHCA32, and are much lower than those reported when a bag-valve-mask (BVM) device is used33,34. Moreover, the use of the i-gel® is not associated with significant leaks during the delivery of continuous chest compressions35. This ensures a high reliability of end-tidal CO2 measurements, an important feature as capnography is increasingly used to monitor and optimize CPR quality and to detect ROSC1.

Our hypothesis was that, in case of OHCA, the early insertion of an i-gel® device without prior BVM ventilation could improve CCF while allowing a similar time than the standard approach to elapse before the first effective ventilation could be delivered.

Objectives

The primary aim of this study was to determine whether the immediate insertion of an i-gel® while providing continuous chest compressions followed by asynchronous ventilations (experimental approach) during the two minutes following the first rhythm analysis allows to generate higher CCFs than the 30 compressions: 2 ventilations (standard) approach in a simulated model of OHCA. 

The secondary objective was to compare the impact of this approach on CPR quality and ventilation parameters1,36,37.
 

Methods

Study design

This was a multicentre, parallel, randomised, superiority, simulation study designed in accordance with the Standard Protocol Items: Recommendations for Interventional Trials (SPIRIT) statement38, the detailed protocol of which was previously published39. It was conducted according to the guidelines of the Declaration of Helsinki. Results are reported according to the Consolidated Standards of Reporting Trials (CONSORT) statement (Supplementary Table S1)40

Ethics declarations

Review and approval were waived by the regional Ethics Committee (CER-Vaud—Commission Cantonale d’Ethique de la Recherche sur l’Être Humain, Lausanne, Switzerland)—REQ-2020-01491—as such studies do not fall under the Swiss Federal Human Research Act. Written informed consent was obtained from all the participants.

Setting

In Switzerland, paramedics follow a 3-year training curriculum and are trained to treat most prehospital emergencies autonomously. They can administer several Advanced Life-Support (ALS) treatments according to emergency care protocols validated by prehospital medical directors. Emergency Medical Technicians (EMTs) graduate after a 1-year curriculum and are trained to assist paramedics. The ALS teams can either be composed of two paramedics or of a paramedic teaming with an EMT. Even though these aspects are standardized, the Swiss federal system generates considerable inter-cantonal heterogeneity between Emergency Medical Services (EMS). In some regions, EMS operating in the same areas have different treatment protocols as each service has its own medical director who can almost singlehandedly decide upon the extent of delegations. This study was performed in four different EMS where paramedics applied the standard 30:2 approach and did not routinely use the i-gel® in case of OHCA.

Participants and recruitment

All registered paramedics and EMTs actively working in either of these EMS were eligible for inclusion. Study team members and participants who did not attend the training path were excluded. Participants were told that the study was about OHCA management, but were not informed of its specific objectives.

Study sequence

The study sequence is summarized in Figure 1. 

Randomization

Randomization was two-tiered. First, to ensure that there would be at least one paramedic per team, an online balanced team generator was used41. Intra-cluster randomization with a 1:1 ratio was then performed using an online randomizer, with each trial center representing a cluster42.

Standardized workshop

The use of the i-gel® device was taught to each team separately by one of the investigators (LSt) in accordance with Peyton’s approach43–45, based on a standard operating procedure (Supplementary Files S2, S3). Twenty minutes were dedicated to this workshop. This took into account the time required to gather the participants’ consent and to allow them to complete a short demographic questionnaire.

Training session of experimental approach

Following the workshop, each team was allowed 20 minutes of self-training supported by a custom-made demonstration video (https://cpr2-intro.swiss-cpr-studies.ch/). During this training session, an experimental approach developed by DT and LSt was practiced. This approach consists in the immediate placement of an i-gel® device by one team member immediately after the first rhythm analysis, without prior BVM ventilation. Meanwhile, the second team member provides continuous chest compressions. Ventilations are given asynchronously at a rate of 10 per minute once the SGA device is in place1,2. After two minutes of continuous chest compressions, 30:2 CPR is provided by one rescuer while the other performs ALS actions.

Study scenario

Another custom-made video, which presented the manikin’s and defibrillator’s characteristics, was displayed to the participants upon entering the study room (https://cpr2-briefing.swiss-cpr-studies.ch/). The scenario was then presented in exactly the same way to all participants regardless of the study site: « This is Michael, a 50-year-old man who suddenly collapsed 10 minutes ago. He is now unconscious, pale, and does not seem to be breathing. Medical reinforcement is already underway and will arrive in about ten minutes. No first responder has been dispatched by the emergency medical call center, and there is no bystander nearby ». Only then could the leader open the opaque, sealed envelope containing the specific airway management strategy the team has to apply. There was no further interaction between participants and the study team until the scenario was stopped. The simulated patient was apneic and in refractory ventricular fibrillation (regardless of the number of defibrillation attempts). The scenario was stopped at T0 (first compression) + 10 minutes.

At the end of the scenario, participants were asked to fill a last questionnaire designed to assess their satisfaction regarding the approach they had applied and the cognitive load they had perceived during the study scenario39. Participants were asked to withhold information regarding the aim and course of the study until data collection had been completed in all four EMS.

Equipment

Apart from the multiparametric monitor/defibrillator which was provided with the simulation manikin (Laerdal SimMan 3G, Laerdal Medical, Stavanger, Norway), all teams had access to their usual resuscitation equipment. A size 4 i-gel® device (Intersurgical Ltd., Wokingham, UK) and a lubricant recommended by the manikin’s manufacturer were added to this equipment.

Study outcomes

Primary outcome

The primary outcome was the CCF achieved during the first two minutes of CPR (starting from first compression). 

Secondary outcomes

Secondary outcomes were: overall (entire 10-minutes scenario) and per-cycle CCF (at 2-4, 4-6, 6-8 and 8-10 minutes); depth of compressions; proportion of compressions within (5 to 6 cm), below (<5 cm) and above (>6 cm) target value; compressions rate; proportion of compressions within (100-120 compressions per minute - cpm), below (<100 cpm) and above target values (>120 cpm); proportion of compressions with complete chest recoil (<5 mm deviation from the reference value); time to first shock; time to first effective ventilation (defined as > 300 ml)46–50; proportions of ventilations within, (300-700 ml), below (< 300 ml) and above (>700 ml) target values; number of ventilations delivered; provider satisfaction; and self-assessed cognitive load.

Data collection, extraction and curation

Most data were automatically collected through the manikin’s sensors and extracted to a comma-separated values (CSV) file, thereby preventing assessment bias. Variables of interest were automatically generated using a custom-coded PHP script51. Data gathered on paper questionnaires were entered in duplicate using EpiData52 and any discrepancy was listed and resolved to minimize copying and typing errors. Missing data were treated as such. No imputation technique was used. All data that could have allowed the data analyst (DT) to identify group allocation were removed (e.g., number of insertion attempts). The groups were renamed “Teysachaux” and “Moléson” and the curated databases were sent in Stata DTA file format for blinded statistical analysis. All investigators were able to access the curated and coded data sets53.

Sample size calculation

Few data were available to help with sample size calculation. We estimated that the mean time needed to deliver two ventilations would amount to approximately 4 seconds, thereby adding up to 20 seconds per cycle. We also estimated that the initial rhythm analysis should take about 8 seconds, thus increasing the no-compression time to around 28 seconds out of the first 120 seconds cycle (23% of no-flow, worth 77% of CCF in the control group). In the experimental group, we estimated that the no-flow should be lower as ventilations were to be provided without interrupting compressions (8 seconds only for rhythm analysis: 7% of no-flow, worth 93% of CCF). Based on observational data from pilot tests and case reviews, data variability was estimated with a standard deviation of 12. Twenty-six teams were therefore required to have a 90% chance of detecting, at the 5% significance level, a difference in CCF from 77% in the control group to 93% in the experimental group. In the original study protocol39, the sample size calculation resulted in 24 teams because it was calculated with an online calculator54, rather than with Stata.

Statistical analysis

Variables were described using either mean (SD or 95%CI) or median [Q1; Q3] according to normality. Student’s t-test or the Mann-Whitney U test were used accordingly. Proportions were reported with their 95% CI. Cognitive load was treated as a continuous variable. User satisfaction was assessed graphically, then tested using Fisher’s exact test. There was a minor protocol deviation as we had initially planned to dichotomize this variable. To avoid losing valuable information, it was however decided not to proceed with dichotomization. This decision was taken after protocol publication, but before completion of data collection and statistical analysis. A two-sided p-value lower than 0.05 was considered significant. All statistical analyses were performed using Stata V15.1 (StataCorp. 2017. Stata Statistical Software: Release 15. College Station, TX: StataCorp LLC).

Results

Fifty-two participants were recruited (44 paramedics and 8 EMTs) between March and May 2021. They were divided into 26 teams allocated equally to both groups (Figure 2). Their characteristics are detailed in Table 1.

Table 1. Participant’s characteristics

 

Standard approach

(n= 26 participants)

Experimental approach

(n = 26 participants)

Age, mean (SD), years

36.6 (9.0)

35.9 (8.0)

Gender, n (%)

- female

- male

- other

 

11 (42.3)

15 (57.7)

0 (0.0)

 

8 (30.8)

18 (69.2)

0 (0.0)

Experience, mean (SD), years

10.3 (8.5)

10.6 (8.3)

Function – Paramedic, n (%)

23 (88.5)

21 (80.8)

Number of i-gel® insertions on manikin in the past year, median (Q1; Q3)

0 (0; 1)

0 (0; 2)

Number of insertions on human in the past year, median (Q1; Q3)

0 (0; 0)

0 (0; 0)

In the experimental group, the successful insertion rate was of 84.6% (11/13) at first try and of 100% at the second one. Among this group, 11/13 teams switched to 30:2 CPR as expected (2 minutes after the first rhythm analysis). The CCF was consistently higher when the experimental approach was used (Table 2). 

Table 2. Chest compression fraction, overall and per cycle expressed as mean (95%CI)

Minutes

Standard approach

Experimental approach

p-value

0 – 2

83.6% (81.2 - 86.1)

89.0% (87.0 - 91.1)

0.001

2 – 4

67.4% (64.6 - 70.2)

79.0% (74.0 - 84.0)

<0.001

4 – 6

63.7% (59.9 - 67.6)

72.0% (67.4 - 76.6)

<0.001

6 – 8

60.1% (57.2 - 63.0)

70.9% (66.2 - 75.6)

<0.001

8 – 10

64.4% (59.5 - 69.3)

71.2% (67.1 – 75.4)

0.03

Overall

67.8% (65.7 - 70.0)

76.4% (73.1 - 79.7)

<0.001

Applying the experimental approach led to shallower compressions with a difference higher than 0.6 cm (median [Q1; Q3] 4.6 cm [4.3; 5.0] versus 5.2 cm [4.9; 5.3], p=0.007). Accordingly, the mean proportion of compressions within the depth target (5 to 6 cm) was lower in the experimental group (41.7% [95%CI 28.2 - 55.3] versus 66.5% [95%CI 51.5 - 81.4], p=0.01). All out-of-target compressions were too shallow as there was no value above target (>6 cm) in either group (Figure 3).

Mean compressions rates were similar in both groups (116 cpm [95%CI 112 – 120] in the experimental group versus 115 cpm [95%CI 110 - 119], p=0.65), with a similar proportion of within-target compressions between groups (median [Q1; Q3] 78.2% [52.9; 92.6] versus 89.9% [62.3; 96.9], p=0.40) (Supplementary Fig. S4). There was no difference regarding chest recoil (median [Q1; Q3] 97.9% [86.7; 99.6] in the experimental group versus 98.9% [92.4; 99.5], p=0.90).

Time to first shock was also similar between groups (mean 41.6 seconds [95%CI 36.1 - 47.2] in the experimental group versus 40.9 [95%CI 34.7 - 47.1], p=0.85), and there was no statistically significant difference regarding time to first ventilation (median [Q1; Q3] 109.0 seconds [90.3; 126.5] versus 102.6 [93.1; 110.1], p=0.74). The number of shocks delivered was slightly higher in experimental group (median [Q1; Q3] 5 [5; 5] versus 4 [4; 5], p=0.05).

The total number of ventilations was more than twice as high in the experimental group (mean 39 [95%CI 33 - 46] versus 19 [95%CI 16 - 23], p<0.001). The proportion of ventilations within target volume was also significantly higher in this group (median 94.6% [Q1; Q3] [88.9; 98.0] versus 81.8% [65.0; 85.7], p=0.003) (Figure 4).

Mean ventilation volume was higher in the experimental group (481 ml [95%CI 430 – 533] versus 385 ml [95%CI 347 to 423], p=0.003); combined with the number of ventilations, this led to a higher minute ventilation (median [Q1; Q3] i-gel® 2044 ml [1709; 2185] versus 662 ml [540; 998], p<0.001). 

There was no difference in self-assessed cognitive load (4.4 [95%CI 3.4 - 5.3] in the experimental group versus 4.7 [95%CI 3.9 - 5.5], p=0.61). Satisfaction was significantly higher in the experimental group (p=0.01) (Supplementary Fig. S5).

Discussion

In this simulation study, the immediate insertion of an i-gel® device led to significantly higher CCFs. This difference can be explained by the ability to immediately provide continuous chest compressions, and by the avoidance of interruptions otherwise necessary to provide ventilations when using a BVM device. CCF was consistently higher during the following cycles, even during one rescuer CPR (applying 30:2 scheme). This implies that using an i-gel® can help decrease no-flow time by overriding the time required to adequately place the ventilation mask. In contradiction with Vogt et al.’s study55, but similarly to Cereceda-Sánchez et al.’s findings56, ventilations were also of higher quality when the i-gel® device was used. Indeed, the number of ventilations provided was more than twice as high in the experimental group, while hyper-insufflations remained anecdotic. These endpoints should be investigated in a pediatric population, as the experimental approach we have described could offer a substantial advantage in pediatric OHCA, where ventilations are paramount57

The number of shocks delivered was slightly higher in the experimental group, but this difference failed to reach statistical significance. As time to first shock and to first ventilation were similar between groups, it seems that, contrarily to the King Laryngeal Tube58, the i-gel® device does not delay the provision of these critical actions.

The present study also supports the use of a short and well-focused learning pathway, as paramedics were able to correctly insert the i-gel® in all cases and without delay to critical actions. Even though a face-to-face workshop is certainly mandatory, the theoretical parts could easily be provided as asynchronous, distance learning interventions59–61.

In our scenario, OHCA had to be managed by two providers only, which represents a worst-case situation. Actual clinical outcomes might prove superior to those we report as CPR-trained bystanders might be assigned to perform high-quality chest compressions while professionals focus on other aspects of OHCA-management, such as team coordination, ventilations, rhythm analysis and ALS treatments.

Compressions were unexpectedly shallower in the experimental group. Two main hypotheses could explain this fact. First, most compressions were delivered in an over-the-head position62–64, and the cumbersome airway management apparatus (i-gel® + antibacterial filter + BVM) coupled with a shallower i-gel® insertion depth in the manikin might have prevented the adequate provision of chest compressions. Second, participants might have been too focused on the i-gel® device, the use of which was new to them, thus downgrading the quality of compressions. Regardless of the actual reasons explaining these shallower compressions, this issue must be fixed before implementation of the i-gel® in the field can be considered. Further studies should now be carried out to assess the most effective way of maintaining an adequate compression depth. These studies could consider two different approaches: forcing participants to deliver compressions from the patient’s side65, using a feedback device66–69, or both together. 

Strengths and limitations

The main limitation is the simulated context, and clinical studies will be needed to validate this experimental approach once the issue regarding the shallow compressions has been addressed. Another limitation is that the recruitment strategy could have biased the sample through a self-selection phenomenon. Randomization should however have mitigated this phenomenon.

The resuscitation sequence outlined in the demonstration video might have been different than the sequence some participants were used to. In this video, both providers initially performed CPR together, and switched to single-rescuer CPR only two minutes after the first shock had been delivered to allow the other rescuer to gain intravenous access.  This might have induced, in both groups, a different strategy than the one they would have chosen in their actual practice, thus affecting BLS quality. Nevertheless, randomization should have smoothened this effect out.

Some outcomes, such as satisfaction, might be overestimated as many participants were eager to increase their skills and knowledge and hoped to autonomously use the i-gel® device in future. In addition, a Hawthorne effect cannot be ruled out as participants knew that they were being observed and that the results would be submitted for publication70. This might have happened despite the fact that participants were unaware of the study outcomes, as it was hardly possible to blind them to the type of intervention.

The strengths of this trial reside in its multicentre design, which allowed the inclusion of paramedics and EMTs from different EMS. The design was also rather original and we believe that our results address a gap regarding the optimal approach in the initial management of OHCA while raising other questions.

Conclusion

After minimal training, paramedics and EMTs using our experimental approach performed better than those applying their standard of care. Our results show that early insertion of an i-gel® device enables higher CCFs and better ventilations in an adult OHCA simulation without delaying time to first ventilation or to first shock. However, compressions depths were significantly shallower when the i-gel® was used, and further studies are needed to understand and fix this issue before clinical trials can be considered.

Declarations

Conflicts of Interest

The authors declare no competing interests.

Acknowledgements

Thanks to the EMS for providing the premises and their warm welcome and to all the paramedics and EMTs for their voluntary participation. Specifically, thanks to André Baumann, Karine Corbat, Gilles Lemasson, Olivier Cassard, Jean-François Pillet, Marc Solioz, and Cédric Frioud for the support.

Funding

“Swissrescue.ch—Website for Prehospital Healthcare Providers” provided funding for the manikin rental. EMS “Genève TEAM Ambulances” lend an ambulance to carry the manikins and provided the study’s supplies (syringes, needles, factices medications, etc...). Protocol’s publication fees were paid by a grant from the EMS “Compagnie d’Ambulances de l’Hôpital du Valais”, Martigny, Valais, and by private funds. Apart from that, this research received no specific grant from any funding agency in the public, commercial or not-for-profit sectors.

Data availability

The datasets generated and analysed during the current study are available in Mendeley Data repository, [https://data.mendeley.com/datasets/98rf9psgvb/1].

Author contributions

Conceptualization (LSt, LJ, DT); Methodoloy (LSt, DT); Software (LSt, LJ); Investigation (LSt, LJ, DT); Data curation (LSt); Formal analysis (DT); Validation (LSt); Resources (LSt, LJ, JS, MB, EP, TS, DT); Writing – Original Draft (LSt); Writing - Review & Editing (LJ, JS, MB, EP, TS, LSu, DT); Visualization (LSt, LJ, JS, MB, EP, TS, LSu, DT); Funding acquisition (LJ, JS); Supervision (LSu); Project administration (LSt, DT). All authors have approved the submitted version.

References

  1. Panchal Ashish R. et al. Part 3: Adult Basic and Advanced Life Support: 2020 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation 142, S366–S468 (2020).
  2. Soar, J. et al. European Resuscitation Council Guidelines 2021: Adult advanced life support. Resuscitation 161, 115–151 (2021).
  3. Rea, T., Olsufka, M., Yin, L., Maynard, C. & Cobb, L. The relationship between chest compression fraction and outcome from ventricular fibrillation arrests in prolonged resuscitations. Resuscitation 85, 879–884 (2014).
  4. Vaillancourt, C. et al. The Impact of Increased Chest Compression Fraction on Return of Spontaneous Circulation for Out-of-Hospital Cardiac Arrest Patients not in Ventricular Fibrillation. Resuscitation 82, 1501–1507 (2011).
  5. Uppiretla, A. K. et al. Effects of Chest Compression Fraction on Return of Spontaneous Circulation in Patients with Cardiac Arrest; a Brief Report. Adv J Emerg Med 4, (2019).
  6. Christenson Jim et al. Chest Compression Fraction Determines Survival in Patients With Out-of-Hospital Ventricular Fibrillation. Circulation 120, 1241–1247 (2009).
  7. Vaillancourt, C. et al. The impact of increased chest compression fraction on survival for out-of-hospital cardiac arrest patients with a non-shockable initial rhythm. Resuscitation 154, 93–100 (2020).
  8. Wik, L. et al. Why do some studies find that CPR fraction is not a predictor of survival? Resuscitation 104, 59–62 (2016).
  9. Bobrow, B. J. et al. Minimally interrupted cardiac resuscitation by emergency medical services for out-of-hospital cardiac arrest. JAMA 299, 1158–1165 (2008).
  10. Shimizu, K. et al. Effect of Advanced Airway Management by Paramedics During Out-of-Hospital Cardiac Arrest on Chest Compression Fraction and Return of Spontaneous Circulation. OAEM 13, 305–310 (2021).
  11. Newell, C., Grier, S. & Soar, J. Airway and ventilation management during cardiopulmonary resuscitation and after successful resuscitation. Critical Care 22, 190 (2018).
  12. Granfeldt, A. et al. Advanced airway management during adult cardiac arrest: A systematic review. Resuscitation 139, 133–143 (2019).
  13. Olasveengen T, Mancini MB, Berg, RA, Brooks S, Castren M, Chung SP, Considine J, Escalante R, Gazmuri R, Hatanaka T, Koster R, Kudenchuk P, Lim SH, Lofgren B, Nation, K, Nishiyma C, Perkins GD, Ristagno G, Sakamoto T, Sayre, M, Sierra A, Smyth M, Stanton D, Travers A, Valliancourt C, Morley P, Nolan J. CPR : Chest Compression to Ventilation Ratio-EMS Delivered. Consensus on Science and Treatment Recommendation [Internet]. Brussels, Belgium: International Liaison Committee on Resuscitation (ILCOR), Basic Life Support Task Force, 2017 July 30. CPR: Chest Compression to Ventilation Ratio - EMS delivered (BLS): Systematic Review. https://costr.ilcor.org/document/cpr-chest-compression-to-ventilation-ratio-ems-delivered.
  14. Carney, N. et al. Prehospital Airway Management: A Systematic Review. Prehosp Emerg Care 1–28 (2021) doi:10.1080/10903127.2021.1940400.
  15. Malinverni, S. et al. Does endotracheal intubation increases chest compression fraction in out of hospital cardiac arrest: A substudy of the CAAM trial. Resuscitation 137, 35–40 (2019).
  16. Kurz, M. C. et al. Association of advanced airway device with chest compression fraction during out-of-hospital cardiopulmonary arrest. Resuscitation 98, 35–40 (2016).
  17. Jensen, J. L., Cheung, K. W., Tallon, J. M. & Travers, A. H. Comparison of tracheal intubation and alternative airway techniques performed in the prehospital setting by paramedics: a systematic review. Canadian Journal of Emergency Medicine 12, 135–140 (2010).
  18. Saracoglu, A. & Saracoglu, K. Advanced airway management in out-of-hospital cardiac arrest – to intubate or not to intubate: a narrative review of the existing literature. Anaesthesiology Intensive Therapy 52, 425–433 (2020).
  19. Buis, M. L., Maissan, I. M., Hoeks, S. E., Klimek, M. & Stolker, R. J. Defining the learning curve for endotracheal intubation using direct laryngoscopy: A systematic review. Resuscitation 99, 63–71 (2016).
  20. Chan, M., Fehlmann, C. A., Pasquier, M., Suppan, L. & Savoldelli, G. L. Endotracheal Intubation Success Rate in an Urban, Supervised, Resident-Staffed Emergency Mobile System: An 11-Year Retrospective Cohort Study. Journal of Clinical Medicine 9, 238 (2020).
  21. Duckett, J., Fell, P., Han, K., Kimber, C. & Taylor, C. Introduction of the i-gel supraglottic airway device for prehospital airway management in a UK ambulance service. Emerg Med J 31, 505–507 (2014).
  22. Wharton, N. M. et al. I-gel insertion by novices in manikins and patients. Anaesthesia 63, 991–995 (2008).
  23. Leventis, C., Chalkias, A., Sampanis, M. A., Foulidou, X. & Xanthos, T. Emergency airway management by paramedics: comparison between standard endotracheal intubation, laryngeal mask airway, and I-gel. Eur J Emerg Med 21, 371–373 (2014).
  24. Castle, N., Owen, R., Hann, M., Naidoo, R. & Reeves, D. Assessment of the speed and ease of insertion of three supraglottic airway devices by paramedics: a manikin study. Emerg Med J 27, 860–863 (2010).
  25. Goliasch, G. et al. Evaluation of advanced airway management in absolutely inexperienced hands: a randomized manikin trial. Eur J Emerg Med 20, 310–314 (2013).
  26. Ruetzler, K. et al. Performance and skill retention of intubation by paramedics using seven different airway devices--a manikin study. Resuscitation 82, 593–597 (2011).
  27. Chauhan, G. et al. Comparison of clinical performance of the I-gel with LMA proseal. J Anaesthesiol Clin Pharmacol 29, 56–60 (2013).
  28. Gabbott, D. A. & Beringer, R. The iGEL supraglottic airway: A potential role for resuscitation? Resuscitation 73, 161–162 (2007).
  29. Middleton, P. M., Simpson, P. M., Thomas, R. E. & Bendall, J. C. Higher insertion success with the i-gel® supraglottic airway in out-of-hospital cardiac arrest: A randomised controlled trial. Resuscitation 85, 893–897 (2014).
  30. Häske, D., Gaier, G., Heinemann, N., Schempf, B. & Renz, J.-U. Minimal training for first responders with the i-gelTM leads to successful use in prehospital cardiopulmonary resuscitation. Resuscitation 134, 167–168 (2019).
  31. Theiler, L. et al. i-gelTM supraglottic airway in clinical practice: a prospective observational multicentre study. British Journal of Anaesthesia 109, 990–995 (2012).
  32. Benger, J. R. et al. Effect of a Strategy of a Supraglottic Airway Device vs Tracheal Intubation During Out-of-Hospital Cardiac Arrest on Functional Outcome: The AIRWAYS-2 Randomized Clinical Trial. JAMA 320, 779–791 (2018).
  33. Stone, B. J., Chantler, P. J. & Baskett, P. J. The incidence of regurgitation during cardiopulmonary resuscitation: a comparison between the bag valve mask and laryngeal mask airway. Resuscitation 38, 3–6 (1998).
  34. Piegeler, T. et al. Evaluation of six different airway devices regarding regurgitation and pulmonary aspiration during cardio-pulmonary resuscitation (CPR) - A human cadaver pilot study. Resuscitation 102, 70–74 (2016).
  35. Häske, D., Schempf, B., Gaier, G. & Niederberger, C. Performance of the i-gelTM during pre-hospital cardiopulmonary resuscitation. Resuscitation 84, 1229–1232 (2013).
  36. Soar, J. et al. Adult Advanced Life Support: 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Resuscitation 156, A80–A119 (2020).
  37. Nolan Jerry P. et al. Executive Summary: 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. Circulation 142, S2–S27 (2020).
  38. Chan, A.-W. et al. SPIRIT 2013 explanation and elaboration: guidance for protocols of clinical trials. BMJ 346, e7586 (2013).
  39. Stuby, L. et al. Effect on Chest Compression Fraction of Continuous Manual Compressions with Asynchronous Ventilations Using an i-gel® versus 30:2 Approach during Simulated Out-of-Hospital Cardiac Arrest: Protocol for a Manikin Multicenter Randomized Controlled Trial. Healthcare 9, 354 (2021).
  40. Schulz, K. F., Altman, D. G. & Moher, D. CONSORT 2010 Statement: updated guidelines for reporting parallel group randomised trials. BMJ 340, c332 (2010).
  41. Keamk - Create random and balanced teams. https://www.keamk.com/.
  42. Online Randomisation List Generator. https://www.sealedenvelope.com/simple-randomiser/v1/lists.
  43. Peyton, J. W. R. Teaching & learning in medical practice. (Manticore Europe Ltd., 1998).
  44. Stuby, L. et al. Impact of Face-to-Face Teaching in Addition to Electronic Learning on Personal Protective Equipment Doffing Proficiency in Student Paramedics: Protocol for a Randomized Controlled Trial. JMIR Res Protoc 10, e26927 (2021).
  45. Giacomino, K., Caliesch, R. & Sattelmayer, K. M. The effectiveness of the Peyton’s 4-step teaching approach on skill acquisition of procedures in health professions education: A systematic review and meta-analysis with integrated meta-regression. PeerJ 8, (2020).
  46. Dörges, V., Ocker, H., Hagelberg, S., Wenzel, V. & Schmucker, P. Optimisation of tidal volumes given with self-inflatable bags without additional oxygen. Resuscitation 43, 195–199 (2000).
  47. Dörges, V. et al. Smaller tidal volumes with room-air are not sufficient to ensure adequate oxygenation during bag-valve-mask ventilation. Resuscitation 44, 37–41 (2000).
  48. Baskett, P., Nolan, J. & Parr, M. Tidal volumes which are perceived to be adequate for resuscitation. Resuscitation 31, 231–234 (1996).
  49. Aramendi, E. et al. A novel technique to assess the quality of ventilation during pre-hospital cardiopulmonary resuscitation. Resuscitation 132, 41–46 (2018).
  50. Serpa Neto, A. et al. Association Between Use of Lung-Protective Ventilation With Lower Tidal Volumes and Clinical Outcomes Among Patients Without Acute Respiratory Distress Syndrome: A Meta-analysis. JAMA 308, 1651 (2012).
  51. Jampen, L. & Stuby, L. CPR - Early Insertion Effect of a Supraglottic Airway Device on CCF in simulated OHCA - PHP code for data extraction from SimMan® 3G. 1, (2021).
  52. Christiansen, T. & Lauritsen, J. EpiData Software - http://www.epidata.dk. https://www.epidata.dk/.
  53. Stuby, L. et al. CPR - Early Insertion Effect of a Supraglottic Airway Device on CCF in simulated OHCA - Dataset. 1, (2021).
  54. Sealed Envelope | Power calculator for continuous outcome superiority trial. https://www.sealedenvelope.com/power/continuous-superiority/.
  55. Vogt, L. et al. Effects of Bag Mask Ventilation and Advanced Airway Management on Adherence to Ventilation Recommendations and Chest Compression Fraction: A Prospective Randomized Simulator-Based Trial. Journal of Clinical Medicine 9, 2045 (2020).
  56. Cereceda-Sánchez, F. J. et al. 7 Bag-valve-mask vs laryngeal mask (I-Gel®) during basic instrumental CPR with capnography monitoring: preliminary results of a randomized cluster trial. BMJ Open 9, (2019).
  57. Lavonas, E. J. et al. Advanced airway interventions for paediatric cardiac arrest: A systematic review and meta-analysis. Resuscitation 138, 114–128 (2019).
  58. Jensen, J. L., Walker, M., LeRoux, Y. & Carter, A. Chest compression fraction in simulated cardiac arrest management by primary care paramedics: King laryngeal tube airway versus basic airway management. Prehosp Emerg Care 17, 285–290 (2013).
  59. Koka, A. et al. Teaching the National Institutes of Health Stroke Scale to Paramedics (E-Learning vs Video): Randomized Controlled Trial. Journal of Medical Internet Research 22, e18358 (2020).
  60. Suppan, L. et al. Effect of an E-Learning Module on Personal Protective Equipment Proficiency Among Prehospital Personnel: Web-Based Randomized Controlled Trial. J Med Internet Res 22, (2020).
  61. Suppan, L. et al. Impact of an e-learning module on personal protective equipment knowledge in student paramedics: a randomized controlled trial. Antimicrob Resist Infect Control 9, (2020).
  62. Perkins, G. D., Stephenson, B. T. F., Smith, C. M. & Gao, F. A comparison between over-the-head and standard cardiopulmonary resuscitation. Resuscitation 61, 155–161 (2004).
  63. Chi, C.-H., Tsou, J.-Y. & Su, F.-C. Comparison of chest compression kinematics associated with over-the-head and standard cardiopulmonary resuscitation. Am J Emerg Med 27, 1112–1116 (2009).
  64. Ćwiertnia, M. et al. Comparison of standard and over-the-head method of chest compressions during cardiopulmonary resuscitation - a simulation study. BMC Emergency Medicine 19, 73 (2019).
  65. Maisch, S. et al. A comparison between over-the-head and standard cardiopulmonary resuscitation performed by two rescuers: a simulation study. J Emerg Med 39, 369–376 (2010).
  66. Davis, D. P. et al. A performance improvement-based resuscitation programme reduces arrest incidence and increases survival from in-hospital cardiac arrest. Resuscitation 92, 63–69 (2015).
  67. Bobrow, B. J. et al. The influence of scenario-based training and real-time audiovisual feedback on out-of-hospital cardiopulmonary resuscitation quality and survival from out-of-hospital cardiac arrest. Ann Emerg Med 62, 47-56.e1 (2013).
  68. Smith, K. et al. 29 Feasibility of using a defibrillator to provide real-time and post-event feedback to paramedics on the quality of their CPR. BMJ Open 9, (2019).
  69. Lakomek, F. et al. Real-time feedback improves chest compression quality in out-of-hospital cardiac arrest: A prospective cohort study. PLoS One 15, e0229431 (2020).
  70. Campbell, J. P., Maxey, V. A. & Watson, W. A. Hawthorne effect: implications for prehospital research. Ann Emerg Med 26, 590–594 (1995).