Objectives
Small Aortic Annulus (AA) is big issue during Aortic Valve Replacement (AVR) necessitating replacement of inappropriate-sized prostheses especially during Double Valve Replacement (DVR). Despite that small aortic valve prostheses can lead to Prosthesis-Patient Mismatch (PPM), there remains reluctance to perform aortic root enlargement (ARE) procedures fearing from morbidity and mortality. We evaluate clinical and echocardiographic outcomes in patients with small AA undergoing DVR.
Methods
The study included 100 consecutive patients underwent DVR for combined rheumatic aortic and mitral valve diseases, between June 2016 and November 2020. Only (50) patients had ARE with DVR. ARE was performed using an autologous or bovine pericardium or Dacron patch by Nick′s or Manouguian procedures. The estimated post-operative end-points were mortality, effective orifice areas (EOA), mean aortic pressure gradient and valve-related complications. The least post-operative follow-up period was 6 months.
Results
The study included 30 male and 70 female patients with mean age of 45 ± 10 years, body surface area (BSA) of 1.6 ± 0.50 m2, aortic annulus diameter was 20 ± 0.4 mm, EOAi was 0.80 ± 0.50 cm2/m2, and aortic mean gradient (PG) 80 ± 40 mm Hg. During follow-up period, there was a mild paravalvular leak (1%) with, (1%) heart block, and residual mean PG on prosthetic aortic valve with all cases of DVR alone.
Conclusion
Enlargement of aortic root by Nick′s or Manouguian technique is safe and effective in patients with small aortic annulus undergoing double valve replacements.