[1] Somani S, Tuan KA, Chernyak D. Corneal asphericity and retinal image quality: a case study and simulations. J Refract Surg, 2004, 20(5): S581-585.
[2] Amigó A, Bonaque-González S, Guerras-Valera E. Control of induced spherical aberration in moderate hyperopic LASIK by customizing corneal asphericity. J Refract Surg, 2015, 31(12):802-806. DOI: 10.3928/1081597X-20151111-03.
[3] Bailey MD, Zadnik K. Outcomes of LASIK for myopia with FDA-approved lasers. Cornea 2007; 26:246–254.
[4] Novis C. Astigmatism and toric intraocular lenses. Curr Opin Ophthalmol. 2000;11(1):47–50.
[5].Villegas EA,Alc6n E,Artal P.Minimum amount of astigmatism that should be corrected[J].J Cataract Refract Surg.2014,40(1):13-19.DOI:10.10160.jer$.2013.09.010.
[6].Dick HB , Kaiser S. Dynamic aberrometry during accommodation of phakic eyes with potentially accommodative lenses [J]. Ophthalmologe,2002,99(11):825-834. DOI:10.1007/s00347-002-0737-3.
[7]. Sales CS, Manche EE. One-year outcomes from a prospective, randomized, eye-to-eye comparison of wavefront-guided and wavefrontoptimized LASIK in myopes. Ophthalmology 2013; 120:2396–2402
[8].Tan J, Simon D, Mrochen M, Por YM. Clinical results of topography-based customized ablations for myopia and myopic astigmatism. J Refract Surg 2012; 28:S829_S836
[9]. Stulting RD, Fant BS, the T-CAT Study Group. Results of topographyguided laser in situ keratomileusis custom ablation treatment with a refractive excimer laser. J Cataract Refract Surg 2015; 42:11–18
[10].Manoj Motwani.The use of WaveLight® Contoura to create a uniform cornea: the LYRA Protocol. Part 3: the results of 50 treated eyes. Clinical Ophthalmology, 2017:11 915–921. http://dx.doi.org/10.2147/OPTH.SI33841
[11]. Manoj Motwani. The use of WaveLight® Contoura to create auniform cornea: the lYra Protocol. Part 1: the effect of higher-order corneal aberrations on refractive astigmatism. Clinical Ophthalmology, 2017:11 897–905. http://dx.doi.org/10.2147/OPTH.SI33839
[12]. Lin DT,Holland SR,Rocha KM,et a1.Method for optimizing topography-guided ablation of highly aberrated eyes with the ALLEGETI'O WAVE excimer laser[J].J Refract Surg,2008,24(4):S439.445.
[13]. Dan Z, Timothy J, J. Bradley R. JRS Standard for Reporting Astigmatism Outcomes of Refractive Surgery. Journal of Refractive Surgery. 2014; 30:654-659. doi:10.3928/1081597X-20140903-01
[14].Alpins NA. A new method of analyzing vectors for changes in astigmatism. J Cataract Refract Surg. 1993;19:524–533.
[15].Estber Moreno B,jesus m,Susana M,Rafael N, Lourdes L, Sergio B. Ocular aberrations before and after myopic corneal surgery: LASIK-induced changes measured with laser ray tracing[J]. Invest Ophthalmol Vis Sci, 2001,42(6): 1396-1403.
[16].Dick HB , Kaiser S. Dynamic aberrometry during accommodation of phakic eyes with potentially accommodative lenses [J]. Ophthalmologe,2002,99(11):825-834. DOI:10.1007/s00347-002-0737-3.
[17]. Xiong ning, Liu yi, Wang ping. Theraperutic effect of wavefront-guided laser in situ keratomileusis for myopic astigmatism. Rec Adv Ophthalmol, 2007:27(6):452-454.
[18]. Duan sufang, Liu jing, Li xiuhong, Liu zhenghua, Song zixuan, Liu xiangling. Clinical study of topography guided off-flap Epi-LASIK in treating traumatic corneal astigmatism. Int Eye Sci, 2014:14(9):1620-1623.
[19]. Zhang jun, Zheng li, Zhao xia, Xu yang, Lin hanjun, Mao hongqian. Clinical study of the contoura automatic location tracking system for correction of ametropia with mild irregular astigmatism. Chin J Optom Ophthalmol, 2018,20(4):216-221. DOI:10.3760/cma.j.issn.1674-845X.2018.04.005.
[20]. Chen kaijian, Bai ji, Liu ting, Ye jiaxin, Kan qiuxia, Liu lina.The effectiveness of topography guided FS-LASIK in treating asymmetric corneal astigmatism. Chin J Optom Ophthalmol, 2016,18(7):394-398.
[21]. ElAHE, Ghanem AA, Saleh SM. Wavefront-optimized ablation versus topography-guided customized ablation in myopic LASIK: comparative study of higher order aberrations. Ophthalmic Surg Lasers Imaging, 2011,42(4):314-320. DOI:10.3928/15428877-20110421-01
[22]. Liu B, Chen W, Shao DW. Using Laser Sight Astrapro Planner 2.2Z software incorneal topography-guided laser in situ kertomileusis for myopia with asymmetric corneal shaper [J]. Int J Ophthalmol, 2014, 7(3):452-456.
DOI:10.3980/j.issn.2222-3959.2014.03.12.
[23]. Lin keji, Chen jun, Lin wen, Lin xiaodong, Zhou yueming, Zheng liangdin. Efficacy of iris lacation to femtosecond combined wavefront guided LASIK for myopic and astigmatism. Int Eye Sci, 2016,16(6):1057-1060.
[24].Ciccio AE, Durrie DS, Stahl JE, Schwendeman F. Ocular cyclotorsion during customized laser ablation. J Refract Surg 2005; 21:S772–S774
[25].Lin qiaoya, Li xuexi, Hu jun. The effect of astigmatic axes' changes by deviation of head and cyclotorsion in LASIK. Chin J Pract Ophthalmol, 2012,30(8):941-944.
[26].Lin DT, Holland SR, Rocha KM, et al. Method for optimizing topography-guid ablation of highly aberrated eyes with the Allegetto wave excimer laser[J]J Refract Surg, 2008,24(4):S439-445.
[27].Manoj Motwani. The use of WaveLight Contoura to create a uniform cornea: the LYRA Protocol. Part 2: the consequences of treating astigmatism on an incorrect axis via excimer laser.Clinical Ophthalmology, 2017:11 907–913.http://dx.doi.org/10.2147/OPTH.SI33840