Wearable ultraviolet (UV) detectors have attracted considerable interest in the military and civilian realms. However, semiconductor-based UV detectors are easily interfered by elongation due to the elastic modulus incompatibility between rigid semiconductors and polymer matrix. Polymer detectors containing UV responsive moieties seriously suffer from slow response time. Herein, a novel UV illuminance-mechanical stress-electric signal conversion has been proposed based on well-defined ionic liquid (IL)-containing liquid crystalline polymer (ILCP) and highly elastic polyurethane (TPU) composite fabrics, to achieve a robust UV monitoring and shielding device with a fast response time of 5 s. Due to the electrostatic interactions and hydrogen bonds between ILs and LC networks, the ILCP-based device can effectively prevent the exudation of ILs and maintain stable performance upon stretching, bending, washing and 1000 testing cycles upon 365 nm UV irradiation. This work provides a generalizable approach toward the development of full polymer-based wearable electronics and soft robots.
Figure 1
Figure 2
Figure 3
Figure 4
There is NO Competing Interest.
This is a list of supplementary files associated with this preprint. Click to download.
Supplementary MOVIE S1
Supplementary MOVIE S2
Supplementary MOVIE S3
Supplementary MOVIE S4
Supplementary MOVIE S5
Loading...
Posted 12 Mar, 2021
Posted 12 Mar, 2021
Wearable ultraviolet (UV) detectors have attracted considerable interest in the military and civilian realms. However, semiconductor-based UV detectors are easily interfered by elongation due to the elastic modulus incompatibility between rigid semiconductors and polymer matrix. Polymer detectors containing UV responsive moieties seriously suffer from slow response time. Herein, a novel UV illuminance-mechanical stress-electric signal conversion has been proposed based on well-defined ionic liquid (IL)-containing liquid crystalline polymer (ILCP) and highly elastic polyurethane (TPU) composite fabrics, to achieve a robust UV monitoring and shielding device with a fast response time of 5 s. Due to the electrostatic interactions and hydrogen bonds between ILs and LC networks, the ILCP-based device can effectively prevent the exudation of ILs and maintain stable performance upon stretching, bending, washing and 1000 testing cycles upon 365 nm UV irradiation. This work provides a generalizable approach toward the development of full polymer-based wearable electronics and soft robots.
Figure 1
Figure 2
Figure 3
Figure 4
Loading...