Abstract The Kocher-Langenbeck (K-L) approach is the standard method for the treatment of posterior wall or column acetabular fractures. This approach allows direct access to the posterior structures of the acetabulum, but is limited cranially and caudally by the neurovascular bundle. The present study was conducted to assess the quality of reduction and the incidence of complications in patients who underwent the modified “one-incision two-window” K-L approach. Methods : This is a Retrospective case series with recruited thirteen consecutive patients from 2015 to 2017 who sustained an acute, displaced posterior wall or column acetabular fracture. All patients were treated with modified “one-incision two-window” K-L approach. Results: The mean operation time, mean intraoperative blood loss, and mean incision wound length were estimated to be 103.8 min (60-120 min), 373.1 mL (100-700 mL), and 9.7 cm (8.0-13.0 cm), respectively. The radiographic quality of reduction was graded as anatomical reduction (maximum residual displacement [MRD] ≤ 2 mm) in all cases, according to Matta’s criteria. Concerning the incidence of complications, there were no iatrogenic neurovascular injury, no surgical site infections, and no osteonecrosis of the femoral head or heterotopic ossification in this cohort. One patient with transverse posterior wall fracture (group 1) experienced deep vein thrombosis in the lesion leg. Another two patients with solitary posterior wall fracture (group 2) developed posttraumatic osteoarthritis, with one diagnosed as Tonnis grade I lesion and the other as Tonnis grade III lesion. With respect to the clinical treatment outcome, the mean visual analogue scale (VAS), mean modified Harris Hip Score (mHHS) and subjective satisfaction rate were 1.7 (1.0-2.0), 90.6 (81-100), and 84.6% (80%-90%), respectively. Although there was no significant difference in the satisfaction rate (82.9% vs. 87.0%, P = 0.941) at 12 months after surgery, group 1 patients had more increased VAS score (2.0 vs. 1.2, P = 0.016) and more decreased mHHS (87.7 vs. 94.6, P = 0.014) than group 2 patients. Conclusions: Our pilot study confirmed that the “one-incision two-window” K-L approach is a simple, safe, reliable, and effective way to manage acute, displaced posterior wall or column acetabular fractures.